Evaluation of the side effects and image quality during fluorescein angiography comparing 2 mL and 5 mL sodium fluorescein.
@article{Moosbrugger2008EvaluationOT, title={Evaluation of the side effects and image quality during fluorescein angiography comparing 2 mL and 5 mL sodium fluorescein.}, author={Karen A Moosbrugger and Tom G. Sheidow}, journal={Canadian journal of ophthalmology. Journal canadien d'ophtalmologie}, year={2008}, volume={43 5}, pages={ 571-5 }, url={https://api.semanticscholar.org/CorpusID:5119692} }
A statistically significant reduction in the quality of angiograms and ease of photography was associated with 2 mL of NaFl, necessitating the termination of the study.
25 Citations
IMAGE QUALITY AND SAFETY OF 300 MG VERSUS 100 MG FLUORESCEIN IN ULTRA-WIDEFIELD FLUORESCEIN ANGIOGRAPHY
- 2025
Medicine
It is demonstrated that a 100 mg low dose of fluorescein provides noninferior image quality compared with a 300 mg dose for ultra-widefield fluorescein angiography, with fewer adverse events.
A lower dose of fluorescein sodium is more suitable for confocal laser endomicroscopy: a feasibility study.
- 2016
Medicine
Randomized, Comparative Study of Full- and Half-Dose Fluorescein Angiography
- 2021
Medicine
In a UWF imaging system, aside from looking at fine microvascular abnormalities, the 250-mg dose of fluorescein provided similar results to a 500-mg doses when using digital ultra-widefield (UWF) technology.
Exploring the optimal fluorescein dose in probe-based confocal laser endomicroscopy for colonic imaging.
- 2011
Medicine
This preliminary study suggests that the optimal dose of fluorescein for high quality pCLE imaging in colon is approximately 5.0 mL.
Lower incidence of contrast-induced nephropathy in patients undergoing fluorescent angiography
- 2017
Medicine
Acute renal function deterioration was not evident in patients undergoing FA regardless of baseline renal function and comorbidities, and Basline SCr and cormorbidity did not predict CIN development.
Probe‐based confocal laser endomicroscopy of the duodenal mucosa with fluorescein dispersion
- 2014
Medicine
In the present study, image quality similar to that of fluorescein given i.v. is obtained by dispersing fluorscein in the duodenal mucosa, and is reported as a world first.
Low-Cost Fluorescein Detection System for High-Grade Glioma Surgery.
- 2016
Engineering, Medicine
Dark purple‐colored colon: Sign of idiopathic mesenteric phlebosclerosis
- 2014
Medicine
In the present study, image quality similar to that of fluorescein given i.v. is obtained by dispersing fluorscein in the duodenal mucosa, and is reported as a world first.
15 References
Efficacy and safety of fluorescein angiography with orally administered sodium fluorescein.
- 1998
Medicine
Frequency of adverse systemic reactions after fluorescein angiography. Results of a prospective study.
- 1991
Medicine
Clinical Comparison of 10% and 25% Intravenous Sodium Fluorescein Solutions
- 1977
Medicine
There is no significant difference in the incidence and severity of adverse reactions between the 10% and 25% solutions, and the overall superiority of the 25% concentration in a 3-ml volume was demonstrated both subjectively and objectively.
Clinical comparison of 10 percent and 25 percent intravenous sodium fluorescein solutions.
- 1977
Medicine
The overall superiority of the 25% concentration in a 3-ml volume was demonstrated both subjectively and objectively in the volunteer study and in the patient study.
Digital fundus imaging: a quality and cost comparison with 35-mm film.
- 1999
Medicine
The quality of digital images is acceptable for diagnostic purposes although resolution is limited, and other advantages and developing technologies will make it increasingly attractive in the future.
USE OF DIRECTLY ACQUIRED DIGITAL FUNDUS AND FLUORESCEIN ANGIOGRAPHIC IMAGES IN THE DIAGNOSIS OF RETINAL DISEASE
- 1987
Medicine
Direct on-line acquisition of digital fundus and fluorescein images is a useful alternative to conventional fundus photography and was used to routinely document the retinal findings in the majority of the clinical patients.
Adverse reactions in intravenous fluorescein angiography.
- 1983
Medicine
No significant difference in the rate of adverse reactions was found when angiography using 10% fluorescein was compared with angiographies of the retina using 25% fluorscein.
Digital fundus imaging: a comparison with photographic techniques.
- 1991
Medicine
Digital fundus imaging is a legitimate alternative to photographic imaging and offers the potential advantage of fewer complications compared with photographic techniques.
A Method of Photographing Fluorescence in Circulating Blood in the Human Retina
- 1961
Medicine
Findings were seen in hypertensive and diabetic patients, and, in addition, neovascularization was clearly defined, and some cotton-wool patches, but not hemorrhages, were found to fluoresce.