Film Dosimetry

Known as: Film Dosimetries, Film Badge Dosimetries, Film Badge Dosimetry 
Use of a device (film badge) for measuring exposure of individuals to radiation. It is usually made of metal, plastic, or paper and loaded with one… Expand
National Institutes of Health

Papers overview

Semantic Scholar uses AI to extract papers important to this topic.
Review
2016
Review
2016
For decades, film was used as a powerful two-dimensional (2D) dosimetry tool for radiotherapy treatment verification and quality… Expand
Review
2012
Review
2012
PURPOSE To provide updated American Brachytherapy Society (ABS) guidelines for transrectal ultrasound-guided transperineal… Expand
  • table 1
  • table 2
  • table 3
  • table 3
  • table 4
Highly Cited
2012
Highly Cited
2012
PURPOSE Radiochromic film provides dose measurement at high spatial resolution, but often is not preferred for routine evaluation… Expand
  • figure 1
  • figure 2
  • figure 3
  • figure 4
  • figure 5
Highly Cited
2011
Highly Cited
2011
PURPOSE A new method to evaluate radiochromic film dosimetry data scanned in multiple color channels is presented. This work was… Expand
  • figure 1
  • table I
  • figure 2
  • figure 3
  • figure 4
Review
2011
Review
2011
  • S. Devic
  • Physica medica : PM : an international journal…
  • 2011
  • Corpus ID: 31802280
In radiation therapy, an accurate dose determination and a precise dose delivery to the tumour are directly associated with… Expand
Highly Cited
2009
Highly Cited
2009
The authors present a radiochromic film dosimetry protocol for a multicolor channel radiochromic film dosimetry system consisting… Expand
  • figure 1
  • figure 2
  • figure 3
  • figure 4
  • figure 5
Highly Cited
2007
Highly Cited
2007
The purpose of this study was to investigate the value of a commercially available flatbed scanner for film dosimetry with… Expand
  • figure 1
  • figure 2
  • figure 3
  • figure 4
  • figure 5
Highly Cited
2007
Highly Cited
2007
The suitability of radiochromic EBT film was studied for high-precision clinical quality assurance (QA) by identifying the dose… Expand
  • table 1
  • figure 1
  • figure 2
  • table 2
  • figure 3
Highly Cited
2005
Highly Cited
2005
In this study, a measurement protocol is presented that improves the precision of dose measurements using a flat-bed document… Expand
Review
1998
Review
1998
Recommendations of the American Association of Physicists in Medicine (AAPM) for the radiochromic film dosimetry are presented… Expand
  • figure 1
  • table I
  • figure 2
  • figure 3
  • figure 4