CdZnTe

Known as: CZT cpd, Cd-Zn-Te, cadmium-zinc-telluride 
 
National Institutes of Health

Topic mentions per year

Topic mentions per year

1985-2017
0204019852017

Papers overview

Semantic Scholar uses AI to extract papers important to this topic.
2008
2008
Next generation high-flux X-ray imaging technology is expected to advance towards multi-color or spectroscopic imaging and will… (More)
  • figure 1
  • figure 2
  • figure 3
  • figure 4
  • figure 5
Is this relevant?
2007
2007
A new CdZnTe gamma-ray spectrometer system that employs two layers of modular detector arrays Is being developed under the… (More)
  • table I
  • figure 2
  • figure 3
  • figure 4
  • figure 5
Is this relevant?
2006
2006
We studied the effects of small, < 20 mum, Te inclusions on the energy resolution of CdZnTe gamma-ray detectors using a highly… (More)
  • figure 3
  • figure 1
  • figure 2
  • figure 4
  • figure 5
Is this relevant?
2006
2006
The performance characteristics of Frisch-ring CdZnTe (CZT) detectors are described and compared with other types of CZT devices… (More)
  • figure 2
  • figure 1
  • figure 3
  • figure 4
  • figure 6
Is this relevant?
2004
2004
A 3D CdZnTe detector can provide 3D position information as well as energy information of each individual interaction when a… (More)
  • figure 1
  • figure 2
  • figure 3
  • figure 4
  • figure 5
Is this relevant?
2004
2004
Three-dimensional (3-D) position-sensitive CdZnTe (CZT) gamma-ray spectrometers employing new VAS3.1/TAT3 ASIC readouts were… (More)
  • figure 1
  • figure 2
  • figure 3
  • figure 4
  • figure 5
Is this relevant?
2003
2003
Two three-dimensional position sensitive CdZnTe gamma-ray spectrometers based on VAS2/TAT2 ASICs were constructed and fully… (More)
  • figure 3
  • figure 1
  • figure 2
  • figure 4
  • figure 5
Is this relevant?
2002
2002
A method to utilize CdZnTe (CZT) detectors in diagnostic x-ray spectroscopy is described in this article. Spectral distortion due… (More)
  • figure 1
  • figure 2
  • figure 3
  • figure 4
  • figure 5
Is this relevant?
2001
2001
A CZT Compton Camera (CCC) is being built using two three-dimensional (3-D) position-sensitive CZT detectors. Expected system… (More)
  • figure 1
  • figure 2
  • figure 3
  • figure 4
  • figure 5
Is this relevant?
Highly Cited
1999
Highly Cited
1999
Two 3-D position-sensitive room temperature semiconductor c-ray spectrometers have been built using 1 cm3 cubic CdZnTe crystals… (More)
  • figure 2
  • figure 3
  • figure 1
  • figure 5
  • figure 4
Is this relevant?