Seismic and Energy Performance Evaluation of Large-Scale Curtain Walls Subjected to Displacement Control Fasteners

@article{Lee2021SeismicAE,
  title={Seismic and Energy Performance Evaluation of Large-Scale Curtain Walls Subjected to Displacement Control Fasteners},
  author={Heonseok Lee and Myung Hwan Oh and Junwon Seo and Woosuk Kim},
  journal={Applied Sciences},
  year={2021},
  url={https://api.semanticscholar.org/CorpusID:237698788}
}
Glass façade curtain walls in buildings is the façade system of choice in modern architecture of mid- to high-rise buildings. This study investigates the seismic and thermal insulation performance of curtain wall systems through structural analysis using the finite element method (FEM) and LBNL Window&Therm insulation analysis. The aim was to optimize the capability of the curtain wall module system and the fastener element technology to respond to displacement and vibration caused by dynamic… 

Structural evaluation of unitized curtain wall systems by using inter-story drift test

A curtain wall enhances the aesthetic appeal of a building and protects it from harmful environmental conditions. As one of the most significant façade curtain walls, Unitized Curtain Wall Systems

Analytical Fragility Curves for Seismic Design of Glass Systems Based on Cloud Analysis

A major advantage is represented by the use of Cloud Analysis in the Cornell’s reliability method, for the seismic assessment of two different case-study glass systems, which are characterized by specific material properties and expected damage mechanisms, restraint details, and dynamic features.

Advanced and emerging materials for testing a curtain wall connection element for improved seismic performance

The research for emerging and disruptive new materials and advanced technologies is a driver of technological innovation in both industry and academia. In this work, the authors present some parts of

Structural Health Monitoring for Prefabricated Building Envelope under Stress Tests

This paper details the comprehensive activities conducted in a laboratory setting to assess the structural health monitoring (SHM) of prefabricated building envelopes. Integrating sensors into

Seismic assessment and finite element modelling of glazed curtain walls

Glazed curtain walls are facade systems frequently chosen in modern architecture for mid and high-rise buildings. From recent earthquakes surveys it is observed the large occurrence of non-structural

Passive Control Systems for the Blast Enhancement of Glazing Curtain Walls Under Explosive Loads

Glass curtain walls are used in modern buildings as envelopes for wide surfaces due to a multitude of aspects. In glass curtain walls, tensile brittle panels are connected through mechanical or

Dynamic Racking Performance of an Earthquake-Isolated Curtain Wall System

Dynamic racking tests, coupled with air leakage tests, were performed on fullsize specimens of a new, Earthquake-Isolated Curtain Wall System and a widely used, conventional curtain wall system (used

Full-scale performance testing and evaluation of unitized curtain walls

Unitized curtain wall systems have been widely seen on high-rise buildings’ facades by bringing benefits with regard to ease of construction, lightness, etc. However, some design and application

Experimental and Numerical Studies on the Failure of Curtain Wall Double Glazed for Radiation Effect

National and international standards for curtain wall glass are focused on wind pressure and insulation performance, but disasters such as fires and earthquakes are not considered. Failure of curtain

Development and Performance Evaluation of Under Cut Anchor Stone Curtain Wall Construction Method

Structural safety as well as variety and aesthetics of building facade are currently gathering more attention in building construction and stone curtain wall is widely used in exterior wall. However,