Ten-year fracture risk predicted by proximal femur Hounsfield units
- Daniel L. ChristensenKyle E. Nappo Scott M. Tintle
- 27 June 2020
Medicine
Bone density measurements using virtual colonoscopy performed for colon cancer screening can provide an early warning sign of patients at potential risk for osteoporosis-related fractures and decreasing HU on CTC may be an earlywarning sign of fracture potential.
Cervical Spine Computed Tomography Hounsfield Units Accurately Predict Low Bone Mineral Density of the Femoral Neck
- Donald F. ColantonioSameer K. SaxenaAlan T VanierDaniel L. RodkeyScott M. TintleScott C. Wagner
- 6 September 2019
Medicine
Study Design: A retrospective cohort. Objective: The objective of this study to determine the correlation between Hounsfield unit (HU) measurements from the C4 vertebral body and dual-energy x-ray…
Prospective Evaluation of Push-up Performance and Patient-Reported Outcomes Following Open Dorsal Wrist Ganglion Excision in the Active-Duty Military Population
- DesRaj M. ClarkMarvin E. Dingle Scott M. Tintle
- 13 August 2021
Medicine
Findings suggest that almost half of active patients may improve push-up performance after DWG excision at 6 months, which is useful when counseling patients undergoing excision.
Bone Mineral Density Mapping of Iliosacral Region: The Use of Hounsfield Units to Optimize Transsacral Screw Trajectory
- Tawney A NakamuraDonald R. FredericksSameer K. SaxenaM. HelgesonScott C. Wagner
- 2 March 2020
Medicine, Engineering
The findings indicate that there is significantly higher BMD density of the anterior ilium and sacral body when compared to the sacral ala at both the S1 and S2 levels.
Low Revision Rates at 10 years for Metal on Metal Hip Implants in a Military Population.
- Sean E. SlavenJ. RichardsSean M. WadeSameer K. SaxenaAlan T VanierJ. Cody
- 1 October 2019
Medicine, Engineering
A retrospective review of patients who underwent MoM total hip arthroplasty (THA) or hip resurfacing (HR) at a military institution from 2006 to 2012 found revision rates of MoM THA and HR in this young, predominantly male population were 2.9% and 5.3%, respectively.
Is it Safe to Use Synthetic Grafts in Pyogenic Vertebral Osteodiskitis When Surgical Debridement is Required?
- Sameer K. SaxenaP. GrimmHusain M. Bharmal
- 1 August 2018
Medicine
Wednesday, September 26, 2018 7:35 AM–9:00 AM ePosters
- Sameer K. SaxenaDonald F. ColantonioScott C. Wagner
- 1 August 2018
Medicine
Thoracic vertebrae HU measurements correlate with low BMD of the femoral neck as determined by DXA scan T-score, and opportunistic utilization of thoracic HU as a screening method provides a simple, quick, and easily assessable screening tool for assessingLow BMD.
Repeated Noise Exposure Does Not Reach Hazardous Levels During Total Joint Arthroplasty.
- Sean E. SlavenBenjamin M. WheatleyDaniel L. ChristensenSameer K. SaxenaRobert Mcgill
- 9 June 2020
Medicine, Environmental Science
Noise exposure in THA and TKA was higher than arthroscopic cases but did not exceed occupational standards; a daily dose percentage of approximately 2% per case indicates that repeated noise exposure likely does not reach hazardous levels in modern arthroplasty practice.
Combat-related acetabular fractures: Outcomes of open versus closed injuries.
- Richard L. PurcellMichael A. DonohueSameer K. SaxenaWade T. GordonLouis Lewandowski
- 1 December 2017
Medicine
A retrospective review of the Department of Defense Trauma Registry into which all US combat-injured patients are enrolled, as well as reviewed local patient medical records, and radiologic studies, found that open acetabular fractures represent a significant challenge in the management of combat-related injuries.
Computed Tomography of the Chest as a Screening Tool for Low Bone Mineral Density.
- Alan T VanierDonald F. ColantonioSameer K. SaxenaDaniel L. RodkeyScott C. Wagner
- 24 December 2021
Medicine
Thoracic vertebrae HU measurements correlate with a low BMD of the femoral neck as determined by DXA T-scores, and a high sensitivity and negative predictive value was achieved with a screening value of 231 HU.