Validation of Fourier decomposition MRI with dynamic contrast-enhanced MRI using visual and automated scoring of pulmonary perfusion in young cystic fibrosis patients.

@article{Bauman2013ValidationOF,
  title={Validation of Fourier decomposition MRI with dynamic contrast-enhanced MRI using visual and automated scoring of pulmonary perfusion in young cystic fibrosis patients.},
  author={Grzegorz Bauman and Michael Puderbach and Tobias Heimann and Annette Kopp-Schneider and Eva Fritzsching and Marcus A Mall and Monika Eichinger},
  journal={European journal of radiology},
  year={2013},
  volume={82 12},
  pages={2371-7}
}
PURPOSE To validate Fourier decomposition (FD) magnetic resonance (MR) imaging in cystic fibrosis (CF) patients with dynamic contrast-enhanced (DCE) MR imaging. MATERIALS AND METHODS Thirty-four CF patients (median age 4.08 years; range 0.16-30) were examined on a 1.5-T MR imager. For FD MR imaging, sets of lung images were acquired using an untriggered two-dimensional balanced steady-state free precession sequence. Perfusion-weighted images were obtained after correction of the breathing… CONTINUE READING