Ultrasonic prediction of graft failure.

Abstract

Forty-six femoro-popliteal by-pass grafts have been followed by serial measurements of the pressure indices in the pedal vessels. By this simple ultrasonic technique it has been possible to predict failure in eleven grafts and effect correction in eight. It is suggested that this represents a valuable method of detecting early remediable lesions and… (More)

Topics

Cite this paper

@article{Taylor1977UltrasonicPO, title={Ultrasonic prediction of graft failure.}, author={R. S. Taylor and Nickole Fox}, journal={The Journal of cardiovascular surgery}, year={1977}, volume={18 3}, pages={309-16} }