True patient-controlled sedation.

@article{Cook1993TruePS,
  title={True patient-controlled sedation.},
  author={L B Cook and Geoffrey G. Lockwood and Christopher C. Moore and James G Whitwam},
  journal={Anaesthesia},
  year={1993},
  volume={48 12},
  pages={1039-44}
}
A modified patient-controlled analgesia pump provided doses of propofol 3 mg or midazolam 0.1 mg in 0.3 ml, over 5.4 s, with no lockout, during transvaginal oocyte retrieval. Alfentanil 0.2 mg was administered at three points during the procedure, and on request. Patients were randomly assigned to receive either propofol (25 patients) or midazolam (22 patients). The mean age, weight, duration of procedure and dose of alfentanil were similar in both groups. Onset of sedation with propofol or… CONTINUE READING

Citations

Publications citing this paper.
Showing 1-9 of 9 extracted citations

Similar Papers