Transfemoral aortic valve implantation with the repositionable Lotus valve compared with the balloon-expandable Edwards Sapien 3 valve.

Abstract

BACKGROUND The rate of paravalvular aortic insufficiency (AI) with transcatheter aortic valve implantation (TAVI) with first generation devices was higher compared with surgical replacement. Residual AI after TAVI has been linked to an increased mortality rate. We compared two second generation TAVI devices - the repositionable Lotus valve with the balloon-expandable Edwards Sapien 3 valve - regarding procedural and 30 day outcome. METHODS AND RESULTS In 78 patients with severe aortic stenosis undergoing transfemoral TAVI we evaluated post-procedural paravalvular AI, device success and early safety according to VARC criteria. Valve size was based on a 256-multislice computed tomography. Patients were followed for 30 days. The Lotus valve (N = 26) and the Edwards Sapien 3 valve (N = 52) were implanted under fluoroscopic guidance. Baseline characteristics were similar between groups. Perimeter derived annulus diameter did not differ with 25.7 ± 1.6mm for Lotus and 25.2 ± 2.1mm for Edwards Sapien 3 patients. After TAVI aortography and transthoracic echocardiography revealed no moderate or severe AI. The rate of mild AI was 12% for Lotus and 15% for Edwards Sapien 3 (p = 0.62). There were no deaths, stroke, annulus rupture or coronary obstruction. Device success was 96% and 98% (p = 0.61), early safety according to VARC 11.5% in both groups (p = 1.0) and the need for pacemaker implantation 27% and 4% (p < 0.003), respectively. CONCLUSIONS TAVI with second-generation devices was associated with no moderate or severe AI and a low rate of mild AI. Device success was high for Lotus and Edwards Sapien 3 while the need for permanent pacemaker was significantly higher with the Lotus valve.

DOI: 10.1016/j.ijcard.2015.05.139
0204060201520162017
Citations per Year

Citation Velocity: 15

Averaging 15 citations per year over the last 3 years.

Learn more about how we calculate this metric in our FAQ.

Cite this paper

@article{Woehrle2015TransfemoralAV, title={Transfemoral aortic valve implantation with the repositionable Lotus valve compared with the balloon-expandable Edwards Sapien 3 valve.}, author={Jochen Woehrle and Birgid Gonska and Christoph Walter Rodewald and Ulrike Trepte and Sabrina Koch and Dominik Scharnbeck and Julia Seeger and Sinisa Markovic and Wolfgang A Rottbauer}, journal={International journal of cardiology}, year={2015}, volume={195}, pages={171-5} }