Transdermal Assessment of Cortisol Awakening Response by Microneedle Perforation Technique

@article{Nomura2012TransdermalAO,
  title={Transdermal Assessment of Cortisol Awakening Response by Microneedle Perforation Technique},
  author={Shusaku Nomura and Masako Ohira and Kenta Suzuki and Ayako Nozaki and Yasuo Kikkawa and Toshiyuki Sato},
  journal={Journal of Life Support Engineering},
  year={2012},
  volume={24},
  pages={48-55}
}
Transdermal assessment of cortisol awakening response (CAR) by microneedle perforation technique was regarded. CAR is a prominent cortisol variation after awakening. Since it has been reported to associate with chronic or daily stress, CAR is assumed as a possible stress indication. However CAR determination by saliva has methodological disadvantages such as lower compliance of multiple specimen collection, bold estimation of total cortisol by discrete sampling time points, etc. We then… 

References

SHOWING 1-10 OF 12 REFERENCES
The Awakening Cortisol Response: Methodological Issues and Significance
TLDR
A review explores reasons for discrepancies in normative data including confounding factors such as gender, age, awakening time, light and participant adherence that suggest the awakening cortisol response is under a distinct regulatory influence different from the rest of the diurnal cortisol secretory cycle.
Increased free cortisol secretion after awakening in chronically stressed individuals due to work overload
TLDR
It is concluded that a repeated measurement of free cortisol in response to awakening should be considered a possible biological correlate of chronic stress.
Salivary cortisol as a biomarker in stress research
Waking levels of salivary biomarkers are altered following sleep in a lab with no further increase associated with simulated night-time noise exposure.
TLDR
Overall sleep quality was rated slightly higher upon awakening from sleep at home, and cortisol and melatonin levels were higher following sleep in the laboratory 30 minutes after awakening, suggesting that these endpoints were not influenced by exposure to noise on the 2nd night.
Measurement of glucose area under the curve using minimally invasive interstitial fluid extraction technology: evaluation of glucose monitoring concepts without blood sampling.
TLDR
These findings validate the adequacy of glucose AUC measurements using MIET and indicate that IG is an adequate substitute for BG, which may be beneficial to patients with diabetes.
Association of diurnal patterns in salivary cortisol with all-cause and cardiovascular mortality: findings from the Whitehall II study.
TLDR
These findings demonstrate, for the first time, the relationship between a flatter slope in cortisol levels across the day and an increased risk of cardiovascular disease mortality in a nonclinical population.
...
...