Transconjunctival sutureless 25-gauge versus 20-gauge standard vitrectomy: correlation between corneal topography and ultrasound biomicroscopy measurements of sclerotomy sites.

@article{Avitabile2010TransconjunctivalS2,
  title={Transconjunctival sutureless 25-gauge versus 20-gauge standard vitrectomy: correlation between corneal topography and ultrasound biomicroscopy measurements of sclerotomy sites.},
  author={T. Avitabile and Francesco Castiglione and Vincenza Bonfiglio and Filippo Castiglione},
  journal={Cornea},
  year={2010},
  volume={29 1},
  pages={
          19-25
        }
}
PURPOSE To determine the correlation between corneal shape changes and ultrasound biomicroscopy (UBM) findings at the sclerotomy sites in conventional 20-gauge (G) pars plana vitrectomy (PPV) and 25-G transconjunctival sutureless vitrectomy (TSV) and to compare the effectiveness of the two surgical methods. DESIGN Prospective, comparative, observational case series. METHODS Sixty consecutive eyes (60 patients) undergoing primary 3-port PPV. Thirty eyes (30 patients, group 20-G) were treated… CONTINUE READING