Traceable dosimetry for MeV ion beams

@article{Garty2022TraceableDF,
  title={Traceable dosimetry for MeV ion beams},
  author={Guy Garty and Andrew D. Harken and David J. Brenner},
  journal={Journal of Instrumentation},
  year={2022},
  volume={17}
}
Standard dosimetry protocols exist for highly penetrating photon and particle beams used in the clinic and in research. However, these protocols cannot be directly applied to shallow penetration MeV-range ion beams. The Radiological Research Accelerator Facility has been using such beams for almost 50 years to irradiate cell monolayers, using self-developed dosimetry, based on tissue equivalent ionization chambers. To better align with the internationally accepted standards, we describe… 

LET-dependence of radiation-induced makers of Immunogenic Cell Death in human cancer cell lines

There are significant cell line-specific differences in the patterns of expression of these key ICD markers, including translocation of calreticulin and extracellular release of high mobility group box 1 protein (HMGB1), and ATP.

References

SHOWING 1-10 OF 31 REFERENCES

AAPM protocol for 40-300 kV x-ray beam dosimetry in radiotherapy and radiobiology.

A new protocol, developed by the Radiation Therapy Committee Task Group 61, for reference dosimetry of low- and medium-energy x rays for radiotherapy and radiobiology is presented, based on ionization chambers calibrated in air in terms of air kerma.

Beam Monitor Calibration for Radiobiological Experiments With Scanned High Energy Heavy Ion Beams at FAIR

Precise and reliable monitoring of the particle rate is of great importance at accelerator facilities worldwide. In this article we describe the standard beam monitor calibration currently employed

Calculation of stopping power ratios for carbon ion dosimetry

Water-to-air stopping power ratio calculations for the ionization chamber dosimetry of clinical carbon ion beams with initial energies from 50 to 450 MeV/u have been performed using the Monte Carlo technique and shows excellent agreement with experimental data.

AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams.

This protocol represents a major simplification compared to the AAPM's TG-21 protocol in the sense that large tables of stopping-power ratios and mass-energy absorption coefficients are not needed and the user does not need to calculate any theoretical dosimetry factors.

FLASH irradiator at the Radiological Research Accelerator Facility.

In both modes of operation of the FLASH irradiator, the expected inverse relation between dose rate and irradiated area is seen, with the highest dose rates obtained for beams with a FWHM of about 2 cm and ±10% uniformity over 1 cm diameter.

Monte Carlo calculated stopping-power ratios, water/air, for clinical proton dosimetry (50-250 MeV).

The large influence of nonelastic nuclear interactions on proton depth-dose distributions shows that the removal of primary protons from the incident beam decreases the peak-to-plateau ratio by a large factor, up to 40% at 250 MeV.

The characterization of the Advanced Markus ionization chamber for use in reference electron dosimetry in the UK

The Classic Markus ionization chamber is found not to meet design requirements for parallel-plate ionization chambers used to determine absorbed dose to water in an electron beam and is not suitable for reference dosimetry in electron beams.

Monte Carlo calculated stopping-power ratios, water/air, for clinical proton dosimetry (50 - 250 MeV)

The large influence of nonelastic nuclear interactions on proton depth - dose distributions shows that the removal of primary protons from the incident beam decreases the peak-to-plateau ratio by a large factor, up to 40% at 250 MeV.

Electron FLASH Delivery at Treatment Room Isocenter for Efficient Reversible Conversion of a Clinical LINAC.

Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry based on Standards of Absorbed Dose to Water

This poster presents a probabilistic procedure for estimating the intensity values of radiolysis-like particles in the presence of X-ray diffraction waves.