Time-Dependent Deflection of Thermoplastic Pipes Under Deep Burial

@article{Sargand2001TimeDependentDO,
  title={Time-Dependent Deflection of Thermoplastic Pipes Under Deep Burial},
  author={Shad M. Sargand and G. Hazen and K. White and Alan Moran},
  journal={Transportation Research Record},
  year={2001},
  volume={1770},
  pages={236 - 242}
}
  • Shad M. Sargand, G. Hazen, +1 author Alan Moran
  • Published 2001
  • Engineering
  • Transportation Research Record
  • Field performance data are presented on the time-dependent deflection of thermoplastic pipes tested at the Ohio Research Institute for Transportation and the Environment (ORITE) at Ohio University in Athens, Ohio. In fall 1999, ORITE began its study of 18 thermoplastic pipe products—12 HDPE (polyethylene) high-density and 6 PVC (polyvinylchloride)—ranging in diameter from 762 to 1524 mm and buried under either 6.1 m or 12.2 m of embankment fill. The installation conditions for these pipes were… CONTINUE READING
    7 Citations

    Figures and Tables from this paper.

    References

    SHOWING 1-6 OF 6 REFERENCES
    POLYETHYLENE PIPE UNDER HIGH FILL
    • 17
    • PDF
    Performance of 1.08-m (42-in.) Diameter HC-HDPE Pipe Under 15.85-m (52-ft) Highway Embankment Fill
    • Presented at the 79th Annual Meeting of the Transportation Research Board
    • 2000
    Performance of 1.08-m (42-in.) Diameter HC-HDPE Pipe Under 15.85-m (52-ft) Highway Embankment Fill. Presented at the 79th Annual Meeting of the Transportation Research
    • 2000
    Structure Evaluation and Performance of Plastic Pipe
    • Report FHWA/OH-98/011. FHWA, U.S. Department of Transportation,
    • 1998
    Thermoplastic Pipe Responses Under Deep Burial Conditions. Presented at the 18th Central Pennsylvania Geotechnical Conference