The threshold force required for femoral impaction grafting in revision hip surgery

@inproceedings{Flannery2010TheTF,
  title={The threshold force required for femoral impaction grafting in revision hip surgery},
  author={Olivia M Flannery and John R Britton and Peter O'Reilly and Nicholas J Mahony and Patrick J. Prendergast and Paddy J Kenny},
  booktitle={Acta orthopaedica},
  year={2010}
}
BACKGROUND AND PURPOSE Femoral impaction grafting requires vigorous impaction to obtain adequate stability without risk of fracture, but the force of impaction has not been determined. We determined this threshold force in a preliminary study using animal femurs. METHODS Adult sow femurs were used because of their morphological similarity to human femurs in revision hip arthroplasty. 35 sow femurs were impacted with morselized bone chips and an increasing force was applied until the femur… CONTINUE READING

References

Publications referenced by this paper.
Showing 1-10 of 24 references

Femoral component revision with used of impacted bonegrafting and a cemented polished stem . Surgical technique

  • W SchreursB, C ArtsJJ, N Verdonschot, P Buma, H SlooffTJJ, M GardeniersJW
  • J Bone Joint Surg ( Am )
  • 2006

Impaction bonegrafting in revision joint replacement surgery

  • D TomsA, L BarkerR, S JonesR, H KuiperJ
  • J Bone Joint Surg ( Am )
  • 2004

Intraopera - tive fracture of the femur in revision total hip arthroplasty with a diaphyseal fitting stem

  • M MeekR, S GarbuzD, A MasriB, V GreidanusN, P. DuncanC
  • J Bone Joint Surg ( Am )
  • 2004

Similar Papers