The promise and perils of exhaled breath condensates.

@article{Effros2004ThePA,
  title={The promise and perils of exhaled breath condensates.},
  author={Richard M. Effros and Marshall Barnett Dunning and Julie A Biller and Reza Shaker},
  journal={American journal of physiology. Lung cellular and molecular physiology},
  year={2004},
  volume={287 6},
  pages={
          L1073-80
        }
}
  • R. Effros, M. Dunning, +1 author R. Shaker
  • Published 1 December 2004
  • Environmental Science
  • American journal of physiology. Lung cellular and molecular physiology
The exhaled breath condensate (EBC) approach provides a convenient and noninvasive approach for sampling the pulmonary epithelial lining fluid (ELF). Increased EBC concentrations of more than a dozen inflammatory markers and hydrogen ions have been reported in lung diseases associated with inflammation. However, the usefulness of EBC is compromised by uncertainties concerning the sources of the EBC droplets and by the extreme and variable dilution of ELF droplets with condensed water vapor… 

Figures and Tables from this paper

Exhaled breath condensate: methodological recommendations and unresolved questions
TLDR
The aim of the American Thoracic Society/European Respiratory Society Task Force on EBC was to identify the important methodological issues surrounding EBC collection and assay, to provide recommendations for the measurements and to highlight areas where further research is required.
[The pH of the exhaled breath condensate: new method for investigation of inflammatory airway diseases].
TLDR
The pH of the condensates has been described in bronchial asthma, acute exacerbations, chronic obstructive lung disease (COPD), and in patients with bronchiectasis, cystic fibrosis and in chronic cough the pH of EBC was also lower, due to the steroid treatment.
Evaluation of H2O2 and pH in exhaled breath condensate samples: methodical and physiological aspects
Abstract This veterinary study is aimed at further standardization of H2O2 and pH measurements in exhaled breath condensate (EBC). Data obtained in the study provide valuable information for many
Urea in exhaled breath condensate of uraemics and patients with chronic airway diseases.
TLDR
It is suggested that there is no need to normalize non-volatile biomarkers in EBC for urea concentrations to account for inter-individual variability, and in repeated measurements within the same individual, the use of urea either as a normalizing factor or as covariate variable could be proposed to control intra- individual variability.
Concentration of exhaled breath condensate biomarkers after fractionated collection based on exhaled CO2 signal.
TLDR
The fractionation of exhaled air may be promising in clinical and occupational medicine and a contribution from the upper airways to oxidative stress biomarkers in apparently healthy subjects is suggested.
Exhaled breath condensate: lessons learned from veterinary medicine.
TLDR
This review summarizes information about the collection and the interpretation of EBC results, particularly with respect to proteins, leukotrienes, hydrogen peroxide, urea, ammonia and pH, based on domestic animal studies.
Possible Impact of Salivary Influence on Cytokine Analysis in Exhaled Breath Condensate
TLDR
The results suggest that the salivary influence on the cytokine assessment in EBC may be negligible.
Methodological aspects of exhaled breath condensate collection and analysis.
  • P. Rosias
  • Environmental Science
    Journal of breath research
  • 2012
TLDR
A simplified methodological approach is proposed that highlights the potential influence of the many techniques used before, during and after condensation of exhaled breath and may serve as a methodological checklist for a more systematical approach of EBC research and development.
Exhaled breath condensate in children: present knowledge and future prospects.
TLDR
Several biomarkers of airway inflammation and oxidative stress have been detected in the EBC of patients, demonstrating the role of different inflammatory pathways in the pathophysiology of respiratory diseases.
...
1
2
3
4
5
...

References

SHOWING 1-10 OF 30 REFERENCES
Exhaled breath condensate pH is a robust and reproducible assay of airway acidity
TLDR
It is concluded that in health, exhaled breath condensate pH is slightly alkaline, held in a narrow range, and is controlled by lower airway source fluid.
A simple method for estimating respiratory solute dilution in exhaled breath condensates.
TLDR
The conductivity of lyophilized samples can be used as an inexpensive, simple, and reliable method for estimating dilution of nonvolatile, hydrophilic mediators in condensates.
Collection and analysis of exhaled breath condensate in humans.
TLDR
The use of this modality in determining host inflammatory response to injury in the lung as well as possible future applications are focused on, particularly its potential use as a single, noninvasive sampling method for point-of-care real-time analysis.
Comparison of nasal and oral inhalation during exhaled breath condensate collection.
TLDR
The data indicate that whereas a greater volume of condensate can be obtained when subjects inhale through their noses, the mode of inhalation does not influence mediator levels in young healthy volunteers, but may affect these levels in patients with allergic rhinitis.
Exhaled breath condensate acidification in acute lung injury.
Dilution of respiratory solutes in exhaled condensates.
TLDR
Large variations in [Na+]cond correlated well with variations of K+ in condensate ([K+] Cond) and Cl− in condenate ([Cl−]cond), and were attributed to differences in respiratory droplet dilution.
Airways in cystic fibrosis are acidified: detection by exhaled breath condensate
TLDR
The hypothesis that airway acidification occurs in cystic fibrosis patients with CF is supported as the pH of the EBC of patients increased significantly with treatment of an exacerbation, although not to control levels.
pH in expired breath condensate of patients with inflammatory airway diseases.
TLDR
In patients with COPD and bronchiectasis, the values of pH were significantly correlated with both sputum neutrophilia and oxidative stress, and in patients with moderate asthma, a significant correlation was observed between pH andSputum eosinophilia, total nitrate/nitrite, and oxidative Stress.
Breath ammonia depletion and its relevance to acidic aerosol exposure studies.
TLDR
It was concluded that acidic oral rinsing is an effective method of reducing airway ammonia, but repeated oral ransing may be required to maintain consistent, low-breath-ammonia conditions during acid aerosol exposure studies.
...
1
2
3
...