The particle size distribution, density, and specific surface area of welding fumes from SMAW and GMAW mild and stainless steel consumables.

@article{Hewett1995ThePS,
  title={The particle size distribution, density, and specific surface area of welding fumes from SMAW and GMAW mild and stainless steel consumables.},
  author={Paul Hewett},
  journal={American Industrial Hygiene Association journal},
  year={1995},
  volume={56 2},
  pages={128-35}
}
  • Paul Hewett
  • Published 1995 in American Industrial Hygiene Association journal
Particle size distributions were measured for fumes from mild steel (MS) and stainless steel (SS); shielded metal arc welding (SMAW) and gas metal arc welding (GMAW) consumables. Up to six samples of each type of fume were collected in a test chamber using a micro-orifice uniform deposit (cascade) impactor. Bulk samples were collected for bulk fume density and specific surface area analysis. Additional impactor samples were collected using polycarbonate substrates and analyzed for elemental… CONTINUE READING
10 Citations
0 References
Similar Papers

Citations

Publications citing this paper.
Showing 1-10 of 10 extracted citations

Similar Papers

Loading similar papers…