The effect of hemoglobin concentration on peritoneal mass transfer and drain volumes in continuous ambulatory peritoneal dialysis.

Abstract

OBJECTIVE To determine whether a correlation exists between hemoglobin levels and peritoneal mass transfer or drain volumes in continuous ambulatory peritoneal dialysis (CAPD) patients. DESIGN Prospective study of two groups of CAPD patients, identified on the basis of their stable hemoglobin levels. Group A--hemoglobin less than 8.5 g/dL; Group B… (More)