The effect of combining two echo times in automatic brain tumor classification by MRS.

@article{GarcaGmez2008TheEO,
  title={The effect of combining two echo times in automatic brain tumor classification by MRS.},
  author={Juan Miguel Garc{\'i}a-G{\'o}mez and Salvador Tortajada and C{\'e}sar Vidal and Margarida Juli{\`a}-Sap{\'e} and Jan Luts and {\`A}ngel Moreno-Torres and Sabine Van Huffel and Carles Ar{\'u}s and Montserrat Robles},
  journal={NMR in biomedicine},
  year={2008},
  volume={21 10},
  pages={1112-25}
}
(1)H MRS is becoming an accurate, non-invasive technique for initial examination of brain masses. We investigated if the combination of single-voxel (1)H MRS at 1.5 T at two different (TEs), short TE (PRESS or STEAM, 20-32 ms) and long TE (PRESS, 135-136 ms), improves the classification of brain tumors over using only one echo TE. A clinically validated dataset of 50 low-grade meningiomas, 105 aggressive tumors (glioblastoma and metastasis), and 30 low-grade glial tumors (astrocytomas grade II… CONTINUE READING