The Morse Taper Junction in Modular Revision Hip Replacement – A Biomechanical and Retrieval Analysis - Die konische Steckverbindung in der modularen Revisionsendoprothetik der Hüfte – Vergleich eines explantierten Prothesenschaftes zur In-vitro-Testung
@inproceedings{Schramm2000TheMT, title={The Morse Taper Junction in Modular Revision Hip Replacement – A Biomechanical and Retrieval Analysis - Die konische Steckverbindung in der modularen Revisionsendoprothetik der H{\"u}fte – Vergleich eines explantierten Prothesenschaftes zur In-vitro-Testung}, author={M. Schramm and D. Wirtz and U. Holzwarth and R. Pitto}, booktitle={Biomedizinische Technik. Biomedical engineering}, year={2000} }
All biomaterials used for total joint surgery are subjected to wear mechanisms. Morse taper junctions of modular hip revision implants are predilection sites for both fretting and crevice corrosion, dissociation and breakage of the components. The aim of this study is to quantify wear and study metallurgical changes of Morse taper junctions of in-vitro and in-vivo loaded modular revision stems. Three modular revision stems (MRP-Titan, Peter Brehm GmbH, Germany) were loaded by a servohydraulic… CONTINUE READING
Figures, Tables, and Topics from this paper
42 Citations
Fracture of the cone of a morse taper junction in revision arthroplasty of the hip
- Medicine
- 2018
- 1
- Highly Influenced
- PDF
Dissociation of a Morse-taper stemmed tibial component following revision total knee arthroplasty. A case report.
- Medicine
- The Journal of bone and joint surgery. American volume
- 2003
- 7
Micromotions at the taper interface between stem and neck adapter of a bimodular hip prosthesis during activities of daily living
- Materials Science, Medicine
- Journal of orthopaedic research : official publication of the Orthopaedic Research Society
- 2013
- 34
Stem Migration and Fretting Corrosion of the Antirotation Pin in the K2/Apex Hip System.
- Medicine
- The Journal of arthroplasty
- 2016
- PDF
Characteristics of wear particles and wear behavior of retrieved PEEK-on-HXLPE total knee implants: a preliminary study
- Materials Science
- 2018
- 8
Uncemented femoral revision arthroplasty using a modular tapered, fluted titanium stem
- Medicine
- Acta orthopaedica
- 2014
- 27
- PDF
Proximal Component Modularity in THA—At What Cost?: An Implant Retrieval Study
- Medicine
- Clinical orthopaedics and related research
- 2012
- 118
- Highly Influenced
References
SHOWING 1-8 OF 8 REFERENCES
Corrosion and wear at the modular interface of uncemented femoral stems.
- Medicine
- The Journal of bone and joint surgery. British volume
- 1994
- 122
- PDF
The tradeoffs associated with modular hip prostheses.
- Medicine
- Clinical orthopaedics and related research
- 1995
- 104
- Highly Influential
Migration of corrosion products from modular hip prostheses. Particle microanalysis and histopathological findings.
- Medicine
- The Journal of bone and joint surgery. American volume
- 1994
- 303
In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling.
- Materials Science, Medicine
- Journal of biomedical materials research
- 1993
- 499
Interface corrosion of a modular head total hip prosthesis.
- Medicine
- The Journal of arthroplasty
- 1992
- 51
The modular morse taper junction in total hip replacement
- Scientific exhibit AAOS Meeting
- 1997
: Revision of femoral stems with bone stock defect
- Proceedings of the 6 th SICOT Trainees Meeting
- 1996
MRP - Titan , ein modulares Konzept für die Revisionshüftprothetik