Tensile fixation strengths of absorbable meniscal repair devices as a function of hydrolysis time. An in vitro experimental study.

@article{Arnoczky2001TensileFS,
  title={Tensile fixation strengths of absorbable meniscal repair devices as a function of hydrolysis time. An in vitro experimental study.},
  author={Steven Paul Arnoczky and M A - Bionx Lavagnino},
  journal={The American journal of sports medicine},
  year={2001},
  volume={29 2},
  pages={118-23}
}
To determine the effect of hydrolysis time on the fixation strength of absorbable meniscal repair devices, adult bovine menisci were repaired with five devices and a suture. The ultimate tensile strength of the repair was then tested in six specimens immediately or after 6, 12, or 24 weeks of incubation at 37 degrees C in a saline solution containing antibiotics, antimycotics, and protease inhibitors. Immediately after implantation the Bionx Meniscus Arrow had a significantly higher failure… CONTINUE READING