Synthetic receive aperture imaging with phase correction for motion and for tissue inhomogeneities. II. Effects of and correction for motion
@article{Trahey1992SyntheticRA, title={Synthetic receive aperture imaging with phase correction for motion and for tissue inhomogeneities. II. Effects of and correction for motion}, author={G. Trahey and L. F. Nock}, journal={IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control}, year={1992}, volume={39}, pages={496-501} }
For Pt.I see ibid., vol.39, p.489 (1992). The effects of tissue/transducer motion and artifacts from adaptive focusing on synthetic receive aperture (SRA) imaging are explored using experiment, simulation, and theory. The impact of these issues on the selection of SRA subaperture geometry is discussed, and a technique to address this problem is demonstrated. The results indicate that SRA with phase correction holds promise in improving ultrasonic image quality.<<ETX>>
133 Citations
Coded Excitation with Directivity Correction in Synthetic Aperture Imaging System
- Computer Science
- 2012
Effects and limitations of motion compensation in synthetic aperture techniques
- Computer Science
- 2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.00CH37121)
- 2000
- 19
Navigator echo motion artifact suppression in synthetic aperture ultrasound imaging
- Computer Science, Medicine
- IEEE Transactions on Biomedical Engineering
- 2005
- 4
- PDF
Duplex synthetic aperture imaging with tissue motion compensation
- IEEE Symposium on Ultrasonics, 2003
- 2003
2-D tissue motion compensation of synthetic transmit aperture images
- Physics
- IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- 2014
- 45
- PDF
Effects of motion on a synthetic aperture beamformer for real-time 3D ultrasound
- Physics
- 1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027)
- 1999
- 27
Multielement synthetic transmit aperture imaging using temporal encoding
- Medicine, Physics
- IEEE Transactions on Medical Imaging
- 2003
- 147
- PDF
A study of synthetic-aperture imaging with virtual source elements in B-mode ultrasound imaging systems
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- 2000
References
SHOWING 1-10 OF 10 REFERENCES
Synthetic receive aperture imaging with phase correction for motion and for tissue inhomogeneities. I. Basic principles
- Computer Science, Medicine
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- 1992
- 110
An evaluation of transducer design and algorithm performance for two dimensional phase aberration correction
- Computer Science
- IEEE 1991 Ultrasonics Symposium,
- 1991
- 19
Two algorithms for correcting phase aberration in a computer-controlled ultrasonic imaging system
- Physics, Computer Science
- [1990] Proceedings. Third Annual IEEE Symposium on Computer-Based Medical Systems
- 1990
- 1
Comparisons of image quality factors for phase aberration correction with diffuse and point targets: theory and experiments
- Physics, Medicine
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- 1991
- 48
Phase-aberration correction using signals from point reflectors and diffuse scatterers: basic principles
- Physics, Medicine
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- 1988
- 452
Phase aberration correction in medical ultrasound using speckle brightness as a quality factor.
- Physics, Medicine
- The Journal of the Acoustical Society of America
- 1989
- 275
Properties of Acoustical Speckle in the Presence of Phase Aberration Part II: Correlation Lengths
- Physics
- 1988
- 52
Flow velocity profile via time-domain correlation: error analysis and computer simulation
- Physics, Medicine
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- 1990
- 239