Sub-angstrom conformational changes of a single molecule captured by AFM variance analysis.

@article{Walther2006SubangstromCC,
  title={Sub-angstrom conformational changes of a single molecule captured by AFM variance analysis.},
  author={Kirstin A. Walther and J. Bruji{\'c} and H. Li and J. Fern{\'a}ndez},
  journal={Biophysical journal},
  year={2006},
  volume={90 10},
  pages={
          3806-12
        }
}
  • Kirstin A. Walther, J. Brujić, +1 author J. Fernández
  • Published 2006
  • Chemistry, Medicine
  • Biophysical journal
  • A system's equilibrium variance can be analyzed to probe its underlying dynamics at higher resolution. Here, using single-molecule atomic-force microscope techniques, we show how the variance in the length of a single dextran molecule can be used to establish thermodynamic equilibrium and to detect conformational changes not directly observable with other methods. Dextran is comprised of a chain of pyranose rings that each undergoes an Angstrom-scale transition from a chair to boat conformation… CONTINUE READING

    Figures, Tables, and Topics from this paper.

    Explore Further: Topics Discussed in This Paper

    Mechanochemistry: one bond at a time.
    • 106
    • PDF
    Single-molecule biophysics: at the interface of biology, physics and chemistry
    • 240
    • PDF

    References

    Publications referenced by this paper.
    SHOWING 1-10 OF 37 REFERENCES
    Force-induced denaturation of RNA.
    • 67