Stator Current and Motor Efficiency as Indicators for Different Types of Bearing Faults in Induction Motors

@article{Frosini2010StatorCA,
  title={Stator Current and Motor Efficiency as Indicators for Different Types of Bearing Faults in Induction Motors},
  author={Lucia Frosini and Ezio Bassi},
  journal={IEEE Transactions on Industrial Electronics},
  year={2010},
  volume={57},
  pages={244-251}
}
This paper proposes a new approach to use stator current and efficiency of induction motors as indicators of rolling-bearing faults. After a presentation of the state of the art about condition monitoring of vibration and motor current for the diagnostics of bearings, this paper illustrates the experimental results on four different types of bearing defects: crack in the outer race, hole in the outer race, deformation of the seal, and corrosion. The first and third faults have not been… CONTINUE READING
Highly Cited
This paper has 131 citations. REVIEW CITATIONS

Citations

Publications citing this paper.
Showing 1-10 of 100 extracted citations

131 Citations

01020'11'13'15'17
Citations per Year
Semantic Scholar estimates that this publication has 131 citations based on the available data.

See our FAQ for additional information.

References

Publications referenced by this paper.
Showing 1-10 of 31 references

Motor bearing damage detection using stator current monitoring

  • R. R. Schoen, T. G. Habetler, F. Kamran, R. G. Bartheld
  • IEEE Trans. Ind. Appl., vol. 31, no. 6, pp. 1274…
  • 1995
Highly Influential
7 Excerpts

Condition Monitoring of Rotating Electrical Machines, 2nd ed

  • P. Tavner, L. Ran, J. Penman, H. Sedding
  • 2008
1 Excerpt

Similar Papers