Spatial Overall Analysis of the Electrostatic Precipitator Casing Load Bearing Performance

@article{Wang2010SpatialOA,
  title={Spatial Overall Analysis of the Electrostatic Precipitator Casing Load Bearing Performance},
  author={Dengfeng Wang and Haijin Dai and Zeng'an Liao and Yuanqing Wang and Yongjiu Shi},
  journal={2010 Asia-Pacific Power and Energy Engineering Conference},
  year={2010},
  pages={1-5}
}
The electrostatic precipitator used in the power plant is the important environmental protection facility to eliminate the flue gas. The casing is the most important technical component. The load bearing mechanism of casing is very complex. The overall load bearing performance of the casing structure is conducted by finite element method. The results of eigenvalue buckling analysis indicate that the first 60 buckling modes present the local buckling under the design load. It implies that the… CONTINUE READING