Simulated characterization of atherosclerotic lesions in the coronary arteries by measurement of bioimpedance

@article{Stiles2003SimulatedCO,
  title={Simulated characterization of atherosclerotic lesions in the coronary arteries by measurement of bioimpedance},
  author={David K. Stiles and Barbara Oakley},
  journal={IEEE Transactions on Biomedical Engineering},
  year={2003},
  volume={50},
  pages={916-921}
}
FEM software was used to determine the feasibility of characterizing various types of atherosclerotic lesions in vivo. This was accomplished by simulating two electrodes as being attached to an angioplasty balloon in the coronary artery. The electrodes on the "balloon" touched and measured the simulated complex impedance of type III, IV, and Va and Vb lesions, as defined by the American Heart Association (AHA). Additionally, the effect of changes in morphology on the complex impedance was… CONTINUE READING
Highly Cited
This paper has 21 citations. REVIEW CITATIONS

Citations

Publications citing this paper.
SHOWING 1-8 OF 8 CITATIONS

References

Publications referenced by this paper.
SHOWING 1-10 OF 10 REFERENCES

Simulation of electrode impedance and current densities near an atherosclerotic lesion

  • D. K. Stiles, B. Oakley
  • Proc. 2nd Annu. Int. IEEE-EMBS Special Topic Conf…
  • 2002
1 Excerpt

Four-electrode null techniques for impedance measurement with high resolution

  • H. P. Schwan, C. D. Ferris
  • Rev. Scientific Instrum., vol. 39, no. 4, p. 481…
  • 1968
1 Excerpt