The reduced energy consumption is highly demand in motor drives for heating, ventilating, and air conditioning (HVAC) applications. [...] Key Method A shaft-mounted position sensor is required for achieving this. This shaft-mounted position sensor increases the cost and reduces the reliability in the drive system. This makes it undesirable for HVAC applications. The objective of this research project is to investigate sensorless control methods for PM synchronous machines with particular attention to HVAC…Expand

Figures, Tables, and Topics from this paper

Permanent-Magnet Synchronous Machine Drives
TLDR
The permanent-magnet synchronous machine (PMSM) drive is one of best choices for a full range of motion control applications and it is being considered in highpower applications such as industrial drives and vehicular propulsion.
Design and control of a low voltage PMSM for electric vehicle application
In order to reduce the CO2 emission, German government's target is to achieve one million electrical cars until 2020 on the German roads. Due to the increased interest in electric vehicles, the
Sensor-less Field Oriented Control of Wind Turbine Driven Permanent Magnet Synchronous Generator Using Flux Linkage and Back EMF Estimation Methods
The study aims at the speed control of the wind turbine driven Permanent Magnet Synchronous Generator (PMSG) by sensor-less Field Oriented Control (FOC) method. Two methods of sensor-less FOC are
Field-Weakening Control Strategy for an Interior Permanent Magnet Synchronous Motor Drive
In this paper a durable flux-weakening control strategy is introduced. Based on this control strategy a vector control of an interior permanent magnet synchronous motor drive is implemented. The new
Critical evaluation and application of position sensorless control techniques for reluctance synchronous machines
TLDR
The RSM is well suited to saliency-based PSC (SB-PSC) methods, which are used to control synchronous machines at startup and low speeds, and is tested and evaluated on three proposed industry applications.
Control of a subsea PMSM with a very long feeding cable using a top-side converter – design and performance evaluation
In oil and gas extraction applications, Permanent Magnet Synchronous Motors (PMSMs) are becoming a more preferred choice to drive Electric Submersible Pumps in order to achieve a higher efficiency
Sensorless control of PMSG-based wind Energy Conversion Systems using a FLL-based synchronization technique
The continuous and accurate information of generator speed in wind energy application is an essential requirement in order to get the maximum power at given tip speed ratio, since the maximum power
An I-f Startup Method for Back-EMF based Sensorless FOC of PMSMs with Improved Stability During the Transition
  • Dunzhi Chen, K. Lu, D. Wang
  • Computer Science
    2020 International Symposium on Industrial Electronics and Applications (INDEL)
  • 2020
TLDR
An I-f startup method with compensation loops, which can move the current vector to the q-axis and fix it there even when load varies, is proposed and Experimental results verify the effectiveness of the proposed method.
Steady-state analysis and comparison of control strategies for PMSM
Permanent Magnet Synchronous Motor (PMSM) has been considered as the best choice for numerous applications. To make PMSM a high performance drive, effective control system is required. Vector control
Super Twisting SMC Based Speed Sensorless PMSM Driven Solar PV Water Pumping System
In this paper, a super twisting sliding mode controller based (ST-SMC) vector controlled speed sensorless permanent magnet synchronous motor (PMSM) driven single stage solar photovoltaic (PV) water
...
1
2
3
4
...

References

SHOWING 1-10 OF 51 REFERENCES
Interior Permanent-Magnet Synchronous Motors for Adjustable-Speed Drives
Interior permanent-magnet (IPM) synchronous motors possess special features for adjustable-speed operation which distinguish them from other classes of ac machines. They are robust high powerdensity
Control of permanent magnet motor drives using a new position estimation technique
Permanent magnet motor drives require absolute position information so that winding currents can be modulated in synchronism with the rotor. The eradication of such sensors has been the subject of
Comparison of two, energy optimizing techniques for PM-machines
Two control methods for energy optimized sensorless control of permanent magnet machines (PM-machines) are studied and implemented. The control of the PM-machine is accomplished without knowledge of
Sensorless PM brushless DC motor drives
  • N. Matsui
  • Engineering, Computer Science
    IEEE Trans. Ind. Electron.
  • 1996
TLDR
The paper presents the speed and position sensorless control of PM brushless DC motors with a sinusoidal flux distribution and a novel starting method is presented by using a salient-pole machine, which demonstrates desired characteristics both in steady-state and starting conditions.
Sensorless rotor-position detection from zero to rated speed for an integrated PM synchronous motor drive
By integrating the motor, the converter and the control circuits of electrical drives into one casing several advantages are obtained. The drive becomes compact, the amount of wiring is significantly
Rotor position and velocity estimation for a salient-pole permanent magnet synchronous machine at standstill and high speeds
This paper addresses self-sensing ("sensorless") control of salient-pole permanent magnet synchronous motors (PMSMs). The major contribution of this work is the introduction of a simple-to-implement
A novel position sensor elimination technique for the interior permanent-magnet synchronous motor drive
  • A. Kulkarni, M. Ehsani
  • Physics
    Conference Record of the IEEE Industry Applications Society Annual Meeting,
  • 1989
An approach to the position sensor elimination of an interior permanent-magnet (IPM) synchronous motor drive is proposed. Analytical equations are developed for the calculation of the phase
High-efficiency drive due to power factor control of a permanent magnet synchronous motor
A drive system of a permanent magnet motor without a magnetic position detector is described. Generally, the position data of a magnet is obtained from the terminal voltage of the motor. In the newly
High performance PMSM drives without rotational position sensors using reduced order observer
  • Joohn-Sheok Kim, S. Sul
  • Engineering, Computer Science
    IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting
  • 1995
TLDR
By introducing the 'angle ambiguity compensation' algorithm, the proposed sensorless scheme has good starting ability and high performance driving characteristics even in the transient state, such as speed fluctuation or speed reversal.
Variable Frequency Synchronous Motor Drives
TLDR
Asynchronous starting at full or reduced line voltage with the help of the damper winding and the short circuited field winding as well as special starting motors are common practice; more recently, large synchronous machines are also started with variable frequency supplied from static inverters.
...