Seismic Analysis of Multi-Storied Building with Shear Walls using ETABS

@article{Jaswanth2018SeismicAO,
  title={Seismic Analysis of Multi-Storied Building with Shear Walls using ETABS},
  author={B. R. B. Jaswanth and Y. Surendra and M. Ravi Kumar},
  journal={International Journal of Current Engineering and Technology},
  year={2018},
  volume={8}
}
Shear walls are structural members used to elongate the strength of R.C.C. structures. These shear walls will be construct in each level of the structure, to form an effective box structure. Equal length shear walls are placed symmetrically on opposite sides of outer walls of the building. Shear walls are added to the building interior to provide more strength and stiffness to the building when the exterior walls cannot provide sufficient strength and stiffness. It is necessary to provide these… 

Tables from this paper

Seismic Analysis of Multi Storied Building with Shear Walls of Different Shapes
A shear wall is a wall that is used to resist the shear, produced due to lateral forces.Shear walls are added to the building interior to provide more strength and stiffness to the building when the
Review on Influence of Provision of Shear Wall in Multistory RC Frame Building
Shear walls are used in tall buildings as supporting elements to resist earthquake loading. In order to enhance the ductility of the structural system the walls are connected together with lateral
Seismic Behaviour Of Rcc Multi Storey Building With Retaining Wall 1
The parking area is provided in the basement floors for most of the buildings. To retain the soil, the basement floor has a retaining wall around the periphery of the building.The outside periphery
Seismic Analysis of RC Residential Multistorey Building for Different Locations of Shear Wall
In the present situation of metropolitan urban areas tall structures are assuming an imperative part as there is lack of area. Step by step trek in the area rates are confronting interest for the
Comparative Study of Seismic Performance in Flat Slab with and without Shear Wall of Multistoried Building in different Earthquake Zone
The effect of vertically irregularities within the seismic overall performance of systems will become definitely vital. Whilst such buildings are built in high seismic zones, the analysis and design
Seismic Performance of Flat Slab Multistory Building with Varying Span - A Review Paper
The necessity of a large headroom is now the essential point of view for any architecture and for that, the only way to solve this as per the structural point of view is to provide a flat slab. The
Comparative Study for the Effect of Rigid and Semirigid Diaphragms on Reinforced Concrete Walls
  • T. S. Mustafa
  • Engineering
    Journal of Engineering Research and Reports
  • 2019
Rigid diaphragm is generally an acceptable option in most of the seismic design codes in which the in-plane deformability is not permitted because of the infinite in-plane stiffness properties. 
GLOBAL STRUCTURAL ANALYSIS OF HIGH-RISE HOSPITAL BUILDING USING EARTHQUAKE RESISTANT DESIGN APPROACH
Building designed has 1 to 8 floors with the quality of concrete f'c of 33.2 MPa, steel quality (fy) 400 MPa, and shear stress of 240 MPa. The building is analyzed by 3D structure modeling through
Base Isolation of Residential Building using Lead Rubber Bearing Technique
-Conventional seismic design practice permits the reduction of forces for designs below the elastic level on the premise, that inelastic action with significant energy dissipation potential in a
Analysis of Effect of Structural Irregularity in Multistorey Building under Seismic Loading
Previous earthquakes in India have discovered that most of the buildings aren't designed to be earthquake resistant. In general, buildings are designed taking into account just the gravity loads. The
...
1
2
...

References

SHOWING 1-10 OF 16 REFERENCES
SEISMIC POUNDING BETWEEN ADJACENT RC BUILDINGS WITH AND WITHOUT BASE ISOLATION SYSTEM
Among the possible structural damages during an earthquake, the seismic induced pounding also has been one of the commonly observed phenomena. This is because the separation gap between many adjacent
Comparative Study of R.C.C, Steel and Composite (G+30 Storey) Building
Steel-concrete composite systems for buildings are formed by connecting the steel beam to the concrete slab or profiled deck slab with the help of mechanical shear connectors so that they act as a
Structural Analysis of a Multi-Storeyed Building using ETABS for different Plan Configurations
TLDR
The case study in this paper mainly emphasizes on structural behavior of multi-storey building for different plan configurations like rectangular, C, L and I-shape.
Building
  • History
  • 2009
new stores, homes, industrial facilities, and road outlets spreading into their neighborhoods. City and regional leaders could ameliorate these conditions if they worked together to plan for future
Design& Analysis of Soft Storey Building due to wind & Earthquake
  • International Journal for Technological Research in Engineering Volume 3, Issue
  • 2016
Talikoti (2015): Review Paper on Seismic Responses of Multi-story RCC Building with Mass Irregularity
  • IJRET: International Journal of Research in Engineering and Technology,
  • 2015
E.I-“Structural analysis of multi storied buildings
  • Author Profile N. Janardhana Reddy received the B. Tech Degree in Civil Engineering from Jawaharlal Nehru Institute
  • 2009
...
1
2
...