Saturation measurements in AC machines using carrier signal injection

@article{Aime1998SaturationMI,
  title={Saturation measurements in AC machines using carrier signal injection},
  author={M. L. Aime and M. W. Degner and R T Lorenz},
  journal={Conference Record of 1998 IEEE Industry Applications Conference. Thirty-Third IAS Annual Meeting (Cat. No.98CH36242)},
  year={1998},
  volume={1},
  pages={159-166 vol.1}
}
This paper presents a technique for measuring the position and magnitude of saliencies in AC machines by injecting a balanced, three-phase, carrier signal. The technique allows detection of where a machine saturates under a full range operating conditions, without any modification to the machine design or construction. From these measurements insight into the causes of saturation and suggestions for improvement in the machine design can be obtained. Experimental results on an induction machine… CONTINUE READING
Highly Cited
This paper has 17 citations. REVIEW CITATIONS