Rupture of the flexor pollicis longus tendon after volar fixed-angle plating of a distal radius fracture: a case report.

@article{Klug2007RuptureOT,
  title={Rupture of the flexor pollicis longus tendon after volar fixed-angle plating of a distal radius fracture: a case report.},
  author={Raymond A Klug and Cyrus M Press and Mark H. Gonzalez},
  journal={The Journal of hand surgery},
  year={2007},
  volume={32 7},
  pages={984-8}
}
We report a case of complete rupture of the flexor pollicis longus tendon 13 months after volar fixed-angle plating of a distal radius fracture. Tendon disruption was associated with a prominent distal volar lip of the plate. The plate was placed at the volar distal lip of the radius, at the location recommended by the manufacturer. Most previous reports of flexor tendon ruptures after volar plating of distal radius fractures have been in improperly placed plates, custom-made plates that were… CONTINUE READING