Role of duplex scan in endoleak detection after endoluminal abdominal aortic aneurysm repair.

@article{Zannetti2000RoleOD,
  title={Role of duplex scan in endoleak detection after endoluminal abdominal aortic aneurysm repair.},
  author={Simona Zannetti and Paola de Rango and Basso Parente and Gianbattista Parlani and Fabio Verzini and Agostino Maselli and Liliane M. Nardelli and Piergiorgio Cao},
  journal={European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery},
  year={2000},
  volume={19 5},
  pages={531-5}
}
OBJECTIVE to validate the role of duplex scan in endoleak detection in postoperative surveillance of endoluminal abdominal aneurysm repair (EAAR). PATIENTS AND METHODS between April 1997 and March 1999, 103 patients were eligible for duplex and computed tomography (CT) scan after EAAR. Mean follow-up was 8 months (range 1-24 months). The study protocol comprised concurrent examination with colour-duplex and CT scan at 1, 6, and 12 months after EAAR, for a total of 198 concurrent examinations… CONTINUE READING