Required minimum granule size in UASB reactor and characteristics variation with size.

@article{Bhunia2007RequiredMG,
  title={Required minimum granule size in UASB reactor and characteristics variation with size.},
  author={Puspendu Bhunia and Makarand Madhao Ghangrekar},
  journal={Bioresource technology},
  year={2007},
  volume={98 5},
  pages={994-9}
}
The objective of this study was to define minimum size of bioparticles that could be classified as granules, to offer all advantages of granular sludge. Based on the theory of sedimentation, the minimum diameter bioparticles, which should be considered as granules was found out for specific gravity of sludge ranging between 1.01 and 1.05. For example, for specific gravity of 1.035 the minimum diameter of granules required for better sludge retention was 0.34 mm. The diameter based on this… CONTINUE READING