Registration of images from sequential MR studies of the brain.

@article{Nelson1994RegistrationOI,
  title={Registration of images from sequential MR studies of the brain.},
  author={S. J. Nelson and Allen B Nalbandian and Edward Proctor and Daniel B. Vigneron},
  journal={Journal of magnetic resonance imaging : JMRI},
  year={1994},
  volume={4 6},
  pages={877-83}
}
For sequential studies of patients with brain tumors, the authors have designed an automated registration procedure for intra- and interexamination alignment of magnetic resonance images. This was evaluated with artificially misregistered data and data from repeat studies of six healthy volunteers and six brain tumor patients. In a subset of cases, a manual procedure based on matching of neuroanatomic landmarks was also applied for comparison. The results showed that the technique is robust and… CONTINUE READING

From This Paper

Topics from this paper.
26 Citations
0 References
Similar Papers

Citations

Publications citing this paper.
Showing 1-10 of 26 extracted citations

Similar Papers

Loading similar papers…