Real time ECG artifact removal for myoelectric prosthesis control.

@article{Zhou2007RealTE,
  title={Real time ECG artifact removal for myoelectric prosthesis control.},
  author={Ping Zhou and Blair A. Lock and Todd A. Kuiken},
  journal={Physiological measurement},
  year={2007},
  volume={28 4},
  pages={397-413}
}
The electrocardiogram (ECG) artifact is a major noise source contaminating the electromyogram (EMG) of torso muscles. This study investigates removal of ECG artifacts in real time for myoelectric prosthesis control, a clinical application that demands speed and efficiency. Three methods with simple and fast implementation were investigated. Removal of ECG artifacts by digital high-pass filtering was implemented. The effects of the cutoff frequency and filter order of high-pass filtering on the… CONTINUE READING