Ray tracing through a grid of blobs

@article{Popescu2004RayTT,
  title={Ray tracing through a grid of blobs},
  author={L. Popescu and R. Lewitt},
  journal={IEEE Symposium Conference Record Nuclear Science 2004.},
  year={2004},
  volume={6},
  pages={3983-3986 Vol. 6}
}
In this paper we describe two ray tracing algorithms for images represented using spherically symmetric basis functions (blobs) on regular grids. The method presented here allows more realistic modeling of the forward projection by considering tube shaped kernels, rather than simple lines. Each kernel is a function of the radial distance r from its center and can vary with the position l along the projection line. The forward projections are computed by convolutions of the kernel with the blob… CONTINUE READING

Citations

Publications citing this paper.
Showing 1-10 of 21 extracted citations

Performance of Philips Gemini TF PET/CT scanner with special consideration for its time-of-flight imaging capabilities.

Journal of nuclear medicine : official publication, Society of Nuclear Medicine • 2007
View 8 Excerpts
Highly Influenced

Advances in time-of-flight PET.

Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics • 2016

References

Publications referenced by this paper.
Showing 1-10 of 10 references

Time of flight PET with lanthanum bromide scintillators

J. S. Karp, S. Surti, +3 authors G. Muehllehner
J. Nucl. Med., vol. 45, no. SNM 51-st Ann. Meet., Abs. Bk. Supp., p. 99P, 2004. • 2004
View 3 Excerpts

Fast ray-tracing technique to calculate line integral paths in voxel arrays

2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515) • 2003
View 1 Excerpt

Rebinning and reconstruction of point source transmission data for positron emission tomography

2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515) • 2003
View 1 Excerpt

A fast ray-tracing technique for TCT and ECT studies

G. Han, Z. Liang, J. You
IEEE Nuclear Science Symposium. Conference Record, vol. 3, pp. 1515–1518, 1999. • 1999
View 1 Excerpt

A fast algorithm to calculate the exact radiological path, through a pixel or voxel space

F. Jacobs, E. Sundermann, M. Christiaens, B. De Sutter, I. Lemahieu
Journal of Computing and Information Technology, vol. 6, no. 1, pp. 89–94, 1998. • 1998