Rapid tracheal intubation with large-dose rocuronium: a probability-based approach.

UNLABELLED There are situations in anesthesia in which it may be desirable to achieve rapid tracheal intubation with perfect conditions, i.e., no coughing or straining. To determine the dose of rocuronium that gives a high probability of achieving perfect conditions for rapid (within 60 s) tracheal intubation, we administered a range of doses of rocuronium… CONTINUE READING