Pull‐Off Strength of Gardner‐Wells Tongs from Cadaveric Crania

@article{Krag1989PullOffSO,
  title={Pull‐Off Strength of Gardner‐Wells Tongs from Cadaveric Crania},
  author={Martin H. Krag and William Byrt and Malcolm Henry Pope},
  journal={Spine},
  year={1989},
  volume={14},
  pages={247–250}
}
Failure of attachment (“pull-off”) of Gardner-Wells tongs from the cranium occasionally occurs, and may cause problems, especially in cases of significant cervical spinal instability. The optimal method for Gardner-Wells tongs attachment is not well defined: the effect on pull-off strength of stem protrusion of the spring-loaded pin, and user accuracy in setting stem protrusion do not appear to be documented In the medical literature. The authors measured pull-off strength from five fresh… Expand
Insertion force measurement of cervical traction tongs: a biomechanical study.
TLDR
Although pin forces generated at the recommended end point for PMT and Gardner- wells tongs appear safe, insufficient force was generated for Ace tongs and overtightening of the Gardner-Wells pins generated loads in excess of those that may be required to penetrate the skull. Expand
Penetration of cranial inner table with Gardner-Wells tongs.
TLDR
The force necessary to penetrate the inner table of the skull well exceeds that exerted by properly applied tongs, suggesting that the risk of inner table penetration is low. Expand
Efficacy and complications of the use of Gardner-Wells Tongs: a systematic review.
TLDR
The complication rate is low, and often associated with only minor and transient complications, which can be easily managed, therefore, GWT are safe and effective, with only rare, more serious complications reported in the literature. Expand
Neurophysiological Changes in Deformity Correction of Adolescent Idiopathic Scoliosis With Intraoperative Skull-Femoral Traction
TLDR
The presence of any MEP recordings irrespective of its amplitude at closure was associated with normal neurological function and the thoracic location of the major curve, increasing Cobb angle, and rigidity of major curve are significant risk factors for changes in MEP with traction. Expand
Systematic review on tele-wound-care in spinal cord injury (SCI) patients and the impact of telemedicine in decreasing the cost
A spinal cord injury (SCI) is damage to the spinal cord that causes changes in its function, either temporary or permanent. These changes translate into loss of muscle function, sensation, orExpand
Abcès cérébral secondaire à l'utilisation de traction crânienne par étrier de Gardner-Wells
TLDR
L'apparition de signes d'irritation locale n'est pas toujours symptomatique d'arrachement; elle ne doit pas faire resserrer le systeme mais inciter a la recherche d'une penetration de the voute crânienne. Expand