Predictive value of preoperative digital templating in THA depends on the surgical experience of the performing physician.
@article{Mittag2012PredictiveVO,
title={Predictive value of preoperative digital templating in THA depends on the surgical experience of the performing physician.},
author={Falk Mittag and Ingmar Ipach and Ralf Schaefer and Christoph Meisner and Ulf G Leichtle},
journal={Orthopedics},
year={2012},
volume={35 2},
pages={
e144-7
}
}Digital preoperative templating is increasingly used to predict the correct component size in total hip arthroplasty (THA). Experienced surgeons could avoid the new technique and rely on a digital template done by a younger colleague. We compared the accuracy of preoperative templating between orthopedic residents (group A) and an experienced orthopedic surgeon (group B). In 106 cases, the software-predicted component sizes of both groups were compared with component sizes placed surgically. An…
14 Citations
The accuracy of digital templating: a comparison of short-stem total hip arthroplasty and conventional total hip arthroplasty
- MedicineInternational Orthopaedics
- 2012
Digital templating of SHA can predict the stem sizes as accurately as conventional THA and is recommendable for SHA, as it helps to predict the implant size prior to surgery and thereby might help to avoid complications.
A Novel Digital Templating Methodology for Arthroplasty: Experience from Patients with Osteonecrosis of the Femoral Head
- MedicineHip international : the journal of clinical and experimental research on hip pathology and therapy
- 2017
Pre-Operative digital templating was useful in predicting cup and stem sizes in patients with ONFH and Radiographic signs of femoral rotation or osteoporotic changes call for appropriate adjustment to improve the accuracy of Templating for THA.
Effects of surgeon experience and patient characteristics on accuracy of digital pre-operative planning in total hip arthroplasty
- MedicineInternational Orthopaedics
- 2020
The fellow-trained group showed better pre-operative planning of complex cases (developmental dysplasia of the hip and avascular necrosis of femoral head) than the resident’s group, and in complex cases, fellow- trained surgeons should assist residents in digitalPre-operative digital templating for THA.
Digital templating in total hip arthroplasty using contralateral healthy hip results in decreased accuracy.
- MedicineActa orthopaedica Belgica
- 2021
Templating acetabular cup size using the ipsilateral diseased hip is more accurate than using the contralateral healthy hip in patients with unilateral OA.
Effect of Body Mass Index on Digital Templating for Total Hip Arthroplasty.
- MedicineThe Journal of arthroplasty
- 2017
Templating Hip Arthroplasty
- MedicineOpen access Macedonian journal of medical sciences
- 2019
It is suggested that preoperative templating is resulting in an enormous increase in the accuracy of total hip arthroplasty and among various methods, King Mark is the most reliable method.
Acetate templating on calibrated standing digital radiograph improves accuracy of preoperative templating for total hip arthroplasty.
- MedicineOrthopaedics & traumatology, surgery & research : OTSR
- 2017
The accuracy and inter-observer reliability of acetate templating in total hip arthroplasty
- MedicineIrish Journal of Medical Science
- 2013
It is concluded that acetate templating on hard copy X-rays is beneficial to surgeons to gauge acetabular cup and femoral stem size to within one size range and helps in predicting nearly exact femoral offset size.
Digital templating without a calibration marker is accurate at predicting implant size for hip hemiarthroplasty
- MedicineEuropean Journal of Trauma and Emergency Surgery
- 2018
Digital templating of radiographs without calibration can be used to accurately and reliably predict femoral head size and offset at a set magnification of 120%.
The accuracy and reliability of preoperative digital 2D templating in prosthesis size prediction in uncemented versus cemented total hip arthroplasty: a systematic review and meta-analysis
- MedicineEFORT open reviews
- 2021
The accuracy of preoperative digital templating in prosthesis size prediction for the planning of cemented or uncemented THA is greater for cemented prostheses, but the inter-observer reliability is greatest for uncements, and the intra-ob server reliability showed a high level of agreement for unCEmented prostheses.
References
SHOWING 1-10 OF 19 REFERENCES
Digital versus conventional templating techniques in preoperative planning for total hip arthroplasty.
- MedicineCanadian journal of surgery. Journal canadien de chirurgie
- 2009
Digital preoperative Templating is as reliable as conventional templating techniques when preoperatively planning for total hip arthroplasty.
Assessment of accuracy and reliability in preoperative templating for hip resurfacing arthroplasty.
- MedicineThe Journal of arthroplasty
- 2010
Digital templating in primary total hip and knee arthroplasty.
- MedicineOrthopedics
- 2010
Digital templating is an effective means for predicting the size of THA and TKA components, thus remaining a viable option as the authors transition into the modern era of digital radiography.
The accuracy of digital templating in uncemented total hip arthroplasty.
- MedicineThe Journal of arthroplasty
- 2010
A comparison of acetate vs digital templating for preoperative planning of total hip arthroplasty: is digital templating accurate and safe?
- MedicineThe Journal of arthroplasty
- 2009
Common errors in the execution of preoperative templating for primary total hip arthroplasty.
- MedicineThe Journal of arthroplasty
- 2010
Determination of accuracy of preoperative templating of noncemented femoral prostheses.
- MedicineThe Journal of arthroplasty
- 1995
The value of preoperative planning for total hip arthroplasty.
- MedicineThe Journal of bone and joint surgery. British volume
- 1998
To analyse the value and accuracy of preoperative planning for total hip replacement (THR), the hand-sketched preoperative plans with the pre- and postoperative radiographs of 100 consecutive primary THRs were digitised electronically and compared.
The value of preoperative planning for total hip arthroplasty
- Medicine
- 1998
To analyse the value and accuracy of preoperative planning for total hip replacement (THR), the hand-sketched preoperative plans with the pre- and postoperative radiographs of 100 consecutive primary THRs were digitised electronically and compared.
A New Digital Preoperative Planning Method for Total Hip Arthroplasties
- MedicineClinical orthopaedics and related research
- 2009
A templating method using a new way of determining the hip magnification with a linear relationship between magnification of the hip and the reference object on top of the pubis symphysis, particularly applicable for preoperative THA when analog methods are replaced by digital methods.