Power System Relaying

@inproceedings{Horowitz1992PowerSR,
  title={Power System Relaying},
  author={Stanley H. Horowitz and Arun G. Phadke},
  year={1992}
}
??????????? ????? Stanley Horowitz H Power System Relaying May 13th, 2020 With emphasis on power system protection from the network operator perspective this classic textbook explains the fundamentals of relaying and power system phenomena including stability protection and reliability The fourth edition brings coverage up to date with important advancements in protective relaying due to significant changes in the conventional electric power system that will 

Figures and Tables from this paper

ADAPTIVE RELAYING IN ELECTRIC POWER SYSTEM PROTECTION

No matter how good the design and construction of electrical power systems, various faults and disturbances are encountered during their operation. Protection systems are used to minimize the effects

Protection Strategies to Mitigate Major Power Systems Breakdowns

This thesis deals with new methods to improve the performance of power system protection in the case of voltage- and transient instability. These methods are designed primarily to mitigate power

Solution to Close-in Fault Problem in Directional Relaying

Directional relays use voltage as the polarizing quantity. When three-phase faults occur close to the relay bus, the available voltage becomes nearly zero and this creates a problem in estimation of

Cyber–physical energy system toward safety in smart grids

A reliable supervisor system (RSS) with fast and precise control ability is proposed to improve power systems and smart grids protection system operations and can effectively corroborate the network stability.

Fault Resistance Influence on Faulted Power Systems with Distributed Generation

This paper proposes an analysis of the RF influence in power system relaying and fault location algorithms with and without DG, allowing future research for fault resistance compensation.

Dynamic influences on protection systems in distribution networks with distributed generation

This paper deals with the protection system in distribution networks with distributed generation. It describes the dynamic influences of synchronous generators on the direction determination of

Relay Lab at NTNU

This thesis presents background on power system protection, relay principles, modern relay technology and relay testing, to support the design, practical set up and proposals for use of a new relay

A Review on Protection of Compensated Power Transmission Line

— This paper presents a survey of present and past developments in the field of protection of transmission lines having FACTS devices and also suggests the best suitable solutions for the problems.
...

References

SHOWING 1-10 OF 40 REFERENCES

Adaptive transmission system relaying

The use of digital techniques to adapt transmission system protection and control to real-time power system changes is investigated and adaptive strategies that minimize the compromises required and thereby optimize system performance are presented.

Fundamental basis for distance relaying with symmetrical components

The paper derives the performance equation of a high speed distance relay which is based upon the theory of symmetrical components. A single equation is shown to be adequate for handling all types of

Negative-Sequence Directional Ground Relaying

  • W. ElmoreJ. Blackburn
  • Business
    Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems
  • 1962
The principles, problems, and solutions in applying negative sequence for directional ground relaying in 3-phase power systems are given in detail. Two general application areas are covered: (1)

The mho-carrier relaying scheme

  • Business
    Electrical Engineering
  • 1944
W. R. Brownlee (Commonwealth and Southern Corporation, Jackson, Mich.): Wartime conditions have accelerated studies of methods of securing maximum emergency capability from transmission lines. It has

Linear couplers for bus protection

THE linear coupler transformer is a constant mutual reactance connecting the primary circuit to the relay. It introduces a new principle into the protective relaying art, a principle∗ that is

Frequency Actuated Load Shedding and Restoration Part II - Implementation

Power systems must be operated within limits that will ensure adequate generation and transmission capacity to avoid cascading. In developing a set of operating limits, it is important to do so

A New Computer Based Integrated Distance Relay For Parallel Transmission Lines

This problem has been analyzed, and a new integrated relaying principle proposed which produces a secure decision to trip only the faulted phases in cases of complex simultaneous faults.

A Half Cycle Bus Differential Relay and its Application

The principles of a new high speed bus differential relay which operates for an internal fault condition within 1 to 2 ms and initiates tripping of circuit breakers in about 7 ms is described. The

Fundamental Basis for Distance Relaying on 3-Phase Systems

In the preceding investigation the quantities upon which distance relays must depend for their operation have been determined for all possible types of faults occurring at a single location. It has

Prolonged Inrush Currents With Parallel Transformers Affect Differential Relaying

  • C. D. Hayward
  • Physics
    Transactions of the American Institute of Electrical Engineers
  • 1941
It has long been known that transient magnetizing inrush currents, sometimes reaching magnitudes as high as eight times full-load current, may flow in a transformer winding for a period following the