The management of intra-articular distal humeral fractures remains a difficult surgical problem. Although an olecranon osteotomy provides excellent exposure for management of these fractures, a number of complications can occur after the creation and repair of the osteotomy including nonunion, malunion, hardware failure, and pain secondary to prominent hardware. In an effort to reduce the incidence of these complications, the senior authors now use contoured 3.5 mm reconstruction plates for the… CONTINUE READING

From This Paper

Topics from this paper.

Citations

Publications citing this paper.
Showing 1-10 of 17 extracted citations

Biomechanical testing of an innovative fixation procedure to stabilize olecranon osteotomy.

Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine • 2014
View 2 Excerpts
Highly Influenced

Bicolumnar 90–90 plating of AO 13C type fractures

Acta orthopaedica et traumatologica turcica • 2017

Evaluation of Surgical Treatment Results of Distal Humeral Fractures

PRACA ORYGINALNA, Dariusz Mątewski, +5 authors KOŚCI RAMIENNEJ