Physico-Chemical and Microbiological Analysis of Potable Water in Jericho and Molete Areas of Ibadan Metropolis
@article{Ladokun2015PhysicoChemicalAM, title={Physico-Chemical and Microbiological Analysis of Potable Water in Jericho and Molete Areas of Ibadan Metropolis}, author={Olusola Abiola Ladokun and Sarah O. Oni}, journal={Advances in Biological Chemistry}, year={2015}, volume={05}, pages={197-202} }
This study was carried out to determine the quality of some water supplies in Jericho and Molete areas in Ibadan, Oyo State, Nigeria. A total of 6 water samples (Jericho and Molete) from well, borehole and public tap were randomly selected and analyzed in triplicate for some physico-chemical and microbial parameters. The pH ranged from 5.88 ± 0.01 to 6.88 ± 0.06 while total hardness ranged from 2.60 ± 0.04 ppm to 44.00 ± 1.20 ppm. The temperature ranged from 15.00℃ ± 0.07℃ to 18.00℃ ± 0.21…
5 Citations
Quality audit of drinking water sources in Ikwo rural setting of Ebonyi State, Southeastern Nigeria
- ChemistryInternational Journal of Energy and Water Resources
- 2020
We assessed the quality status of surface and ground waters used for drinking in Ikwo, Southeast Nigeria, using the physicochemical and bacteriological qualities, and antimicrobial susceptibility…
Physico-Chemical and Microbiological Analysis of Water of the “Presa De Los Patos” in the Desierto De Los Leones National Park, Mexico
- Environmental Science
- 2017
It was determined that the water of the Presa de los Patos cannot be considered potable and the water consumption is a great risk for the habitants and visitors of the park.
Quality assessment of waterside river, ogbor hill, aba I: effect of three-point samples on some hematological parameters of wistar rats
- Environmental Science
- 2017
Out of the three natural water forms (liquid, solid and gaseous forms), liquid water is the commonly used and can be sourced from streams, lakes, rivers, ponds and wells.1 Rivers are considered…
Physico-Chemical Analysis of Drinking Water in Hanumangarh District, Rajasthan India
- Biology, Engineering
- 2016
Water samples taken at twenty different locations along Hanumangarh District and were subjected to physicochemical analysis found the result to range between 7.05-7.50, Electrical conductivity was found to be between 0.31-0.52 mmho/cm and the lowest value of Chloride, 32.5mg/l was recorded at location C19.
Seasonal Assessment of Underground Water Quality
- 2017
Levels of physiochemical parameters and heavy metals in water collected in dry and wet seasons from some boreholes in Wamba Area of Nasarawa state, Nigeria were assessed. Physicochemical parameters…
References
SHOWING 1-9 OF 9 REFERENCES
Clonal Populations of ThermotolerantEnterobacteriaceae in Recreational Water and Their Potential Interference with Fecal Escherichia coli Counts
- BiologyApplied and Environmental Microbiology
- 2001
Findings demonstrate that E. coli is a better indicator of fecal pollution than fecal coliforms, which may replicate in the environment and falsely elevate indicator organism levels.
Microbiology An Introduction
- Biology
- 1983
Part 1 Fundamentals of microbiology: the microbial world and you chemical principles observing microorganisms through a microscope functional anatomy of procaryotic and eucaryotic cells microbial…
Water Quality Assessments: A Guide to the Use of Biota, Sediments and Water in Environmental Monitoring
- Environmental Science
- 1992
An introduction to water quality strategies for water quality assessment the selection of water quality variables the use of particulate material the use of biological material rivers lakes and…
Typhoid perforation: factors affecting mortality and morbidity.
- Medicine
- 1982
The experience suggests that the hematoxicity of this drug has been over-rated and that Chloramphenicol in massive doses is indicated for all these patients.
10.321/eid0805.Typical and Atypical Enteropathogenic Escherichia coli
- MedicineEmerging infectious diseases
- 2002
Atypical EPEC is more closely related to Shiga toxin–producing E. coli (STEC), and like STEC these strains appear to be emerging pathogens.
Operative treatment of typhoid perforation with peritoneal irrigation: a comparative study.
- MedicineGut
- 1980
The results obtained have convinced us that all cases of typhoid must be promptly and adequately resuscitated, operated, drained, and irrigated.
Typical and Atypical Enteropathogenic Escherichia coli
- Medicine
- 2001
Atypical EPEC is more closely related to Shiga toxin–producing E. coli (STEC), and like STEC these strains appear to be emerging pathogens.
Standard Methods for the Examination of Water and Wastewater seventh edition
- Engineering
- 2013
Standard Methods for the Examination of Water and Wastewater seventh edition , Standard Methods for the Examination of Water and Wastewater seventh edition , کتابخانه دیجیتال جندی شاپور اهواز