Photoplethysmography: Beyond the Calculation of Arterial Oxygen Saturation and Heart Rate

@article{Shelley2007PhotoplethysmographyBT,
  title={Photoplethysmography: Beyond the Calculation of Arterial Oxygen Saturation and Heart Rate},
  author={Kirk H. Shelley},
  journal={Anesthesia \& Analgesia},
  year={2007},
  volume={105},
  pages={S31-S36}
}
  • K. Shelley
  • Published 1 December 2007
  • Medicine
  • Anesthesia & Analgesia
In this article, I examine the source of the photoplethysmograph (PPG), as well as methods of investigation, with an emphasize on amplitude, rhythm, and pulse analysis. The PPG waveform was first described in the 1930s. Although considered an interesting ancillary monitor, the “pulse waveform” never underwent intensive investigation. Its importance in clinical medicine was greatly increased with the introduction of the pulse oximeter into routine clinical care in the 1980s. Its waveform is now… 

Figures and Tables from this paper

Advances in photoplethysmography: beyond arterial oxygen saturation

Clinical comparative effectiveness studies are still needed in order to determine if these technologies can be translated into improvement of relevant patient outcomes, as well as to comment on trials evaluating their accuracy and clinical application.

Photoplethysmographic variability analysis in critical care — Current progress and future challenges

An overview of the current progress towards the application of PPG waveform variability (PPGV) in emergency and intensive care and translation of research findings into clinical practice is provided.

Spontaneous fluctuations in the peripheral photoplethysmographic waveform: roles of arterial pressure and muscle sympathetic nerve activity.

Spontaneous PPG variability in the ear includes a major contribution from arterial pressure and MSNA, which may provide a rationale for its clinical utility and highlight the differential mechanisms governing PPG waveform fluctuations across different body sites.

A series of case studies on detection of spontaneous pulse by photoplethysmography in cardiopulmonary resuscitation.

Evaluation of a multimode photoplethysmographic sensor during cuff-induced hypoperfusion

A new multimode PPG measurement system which utilizes a reflectance PPG probe that operates in reflectance, transmittance and transreflectance mode simultaneously aiming to improve the quality of the PPG signals in cases of poor peripheral perfusion is developed.

A Review of Signal Processing Used in the Implementation of the Pulse Oximetry Photoplethysmographic Fluid Responsiveness Parameter

It is concluded that to develop a robust, fully automated &Dgr;POP algorithm for use in the clinical environment, more rigorous signal processing is required.

Pulse Oximetry: Beyond SpO2

  • D. Hess
  • Medicine
    Respiratory Care
  • 2016
With technology improvements, the use of pulse oximetry to detect SpCO, SpMet, SpHb, pulsus paradoxus, breathing frequency, and fluid responsiveness is likely to improve in the future.

Investigations of photoplethysmography in the assessment of haemodynamics, vascular mechanics and haemorheology

Results from the in vivo and in vitro investigations strongly suggest that PPG has the potential to be used as a non‐invasive and continuous method for the assessment of cardiovascular disease markers such as blood pressure, arterial stiffness and blood viscosity.

On the Analysis of Fingertip Photoplethysmogram Signals

  • M. Elgendi
  • Computer Science
    Current cardiology reviews
  • 2012
Different types of artifact added to PPG signal, characteristic features of PPG waveform, and existing indexes to evaluate for diagnoses are discussed.
...

References

SHOWING 1-10 OF 37 REFERENCES

Pulse Oximetry and Circulatory Kinetics Associated with Pulse Volume Amplitude Measured by Photoelectric Plethysmography

It is concluded that the PVA of the PEPG is determined mainly by venous pulse volume generated by shunting of arterial pulse via open arteriovenous anastomoses in the cutaneous circulation.

The Use of Joint Time Frequency Analysis to Quantify the Effect of Ventilation on the Pulse Oximeter Waveform

Joint time frequency analysis of the pulse oximeter waveform can be used to determine the respiratory rate of ventilated patients and to quantify the impact of ventilation on the waveform.

What Is the Best Site for Measuring the Effect of Ventilation on the Pulse Oximeter Waveform?

It was found that the respiratory signal in the pulse oximeter waveform was more than 10 times stronger in the region of the head when compared with the finger, which was true with both controlled positive pressure ventilation and spontaneous breathing.

Use of Pulse Oximetry as a Noninvasive Indicator of Intravascular Volume Status

Pulse oximeters providing a continuous display of the pulse waveform offer a new method of estimating relative volume status during positive-pressure ventilation, which has previously been shown to be a sensitive indicator of hypovolemia.

Arterial–Pulse Oximetry Loops: A New Method of Monitoring Vascular Tone

The off-line calculation of the vascular compliance of the finger is reported and the continuous on-line use of this methodology is suggested as an aid to monitoring the peripheral vascular resistance.

Estimation of breathing interval from the photoplethysmographic signals in children

Preliminary findings herein suggest that besides having the capability to monitor HR and arterial blood oxygen saturation measurements, the PPG signals can be used to derive BI for children, which can be an attractive alternative for children who are more disturbed by intrusive techniques in prolonged clinical monitoring.

A New Probe for Ankle Systolic Pressure Measurement Using Photoplethysmography (PPG)

A new photoplethysmographic probe that uses near-infrared light (880 nm) to detect pulsatory blood flow underneath the distal end of a standard pneumatic cuff is presented, adapted to the anatomical conditions at the ankle, permitting recording of pressures in both ankle arteries separately.

Neural network for photoplethysmographic respiratory rate monitoring

  • A. Johansson
  • Medicine
    European Conference on Biomedical Optics
  • 2001
Results suggest the use of a combined PPG system for simultaneous monitoring of respiratory rate and arterial oxygen saturation (pulse oximetry) and a neural network was assessed in a combined pattern recognition approach.

Pulse oximeter as a sensor of fluid responsiveness: do we have our finger on the best solution?

Future studies including volume challenge must be performed to test whether the pulse oximetry waveform can really serve as a nonivasive tool for the guidance of fluid therapy in patients receiving mechanical ventilation in intensive care units and in operating rooms.

Photo-electric plethysmography as a monitoring device in anaesthesia. Application and interpretation.

Physiologically, changes in blood volume pulsations depend on the distensibility of the vessel wall as well as on the intravascular pulse pressure, and it is shown that changes in the height of ventilatory waves may be of diagnostic significance.