Performance of the GRETA prototype detectors
@article{Vetter2000PerformanceOT, title={Performance of the GRETA prototype detectors}, author={Kai Vetter and A. Kuhn and I. Y. Lee and R. M. Clark and Mario Cromaz and M. A. Deleplanque and Richard M. Diamond and Paul J. Fallon and G. J. Lane and A. O. Macchiavelli and Michael R. Maier and Frank S. Stephens and C. E. Svensson and H. Yaver}, journal={Nuclear Instruments \& Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment}, year={2000}, volume={452}, pages={105-114} }
85 Citations
Scanning of a Double-Sided Germanium Strip Detector
- PhysicsEPJ Web of Conferences
- 2021
This work presents the results from the characterization of a Position-Sensitive Planar Germanium (PSPGe) detector. The PSPGe detector is a double-sided orthogonal strip detector consisting of 10x10…
A study of the effects of position resolution and energy resolution on Compton imaging using a single planar strip detector
- Physics
- 2016
The feasibility of single element Compton imaging using a Double Sided Germanium Strip Detector (DSGSD) has been investigated, with potential use in assisting particle identification as part of Phase…
Digital gamma-ray tracking algorithms in segmented germanium detectors
- Physics, Computer Science
- 2002
It was found that for gamma rays of energies around 1 MeV, a ratio of photopeak counts to total counts of 2:3 could be obtained using the tracking algorithm, with only a 2% reduction in detection efficiency, compared to the untracked data.
Tracking $ \gamma$γ rays in highly segmented HPGe detectors: A review of AGATA and GRETINA
- PhysicsThe European Physical Journal A
- 2019
Abstract.The AGATA and GRETINA/GRETA tracking spectrometers allow for the highest sensitivity $ \gamma$γ -ray spectroscopy achievable today. Central to these instruments is the task of tracking $…
References
SHOWING 1-2 OF 2 REFERENCES
Nucl
- Phys. A 520
- 1990