Performance of near-infrared spectroscopy in measuring local O(2) consumption and blood flow in skeletal muscle.

@article{vanBeekvelt2001PerformanceON,
  title={Performance of near-infrared spectroscopy in measuring local O(2) consumption and blood flow in skeletal muscle.},
  author={Mireille C. P. van Beekvelt and Willy Colier and Ron A. Wevers and Baziel G.M. van Engelen},
  journal={Journal of applied physiology},
  year={2001},
  volume={90 2},
  pages={
          511-9
        }
}
The aim of this study was to investigate local muscle O(2) consumption (muscV(O(2))) and forearm blood flow (FBF) in resting and exercising muscle by use of near-infrared spectroscopy (NIRS) and to compare the results with the global muscV(O(2)) and FBF derived from the well-established Fick method and plethysmography. muscV(O(2)) was derived from 1) NIRS using venous occlusion, 2) NIRS using arterial occlusion, and 3) the Fick method [muscV(O(2(Fick)))]. FBF was derived from 1) NIRS and 2… Expand
Noninvasive optical quantification of absolute blood flow, blood oxygenation, and oxygen consumption rate in exercising skeletal muscle.
TLDR
The application of NIRS/DCS technology to quantitatively evaluate hemodynamic and metabolic parameters in exercising skeletal muscle holds promise for improving diagnosis and treatment evaluation for patients suffering from diseases affecting skeletal muscle and advancing fundamental understanding of muscle and exercise physiology. Expand
Measurement of muscle blood flow and O2 uptake via near-infrared spectroscopy using a novel occlusion protocol
TLDR
These findings indicate that the COMBO method provides valid estimates of flexor digitorum superficialis muscle blood flow and O 2 uptake and, to a slightly lesser extent, there was a tendency for COMBO trials to underestimate. Expand
Muscle oxygen consumption, determined by NIRS, in relation to external force and EMG.
TLDR
The findings suggest that load sharing is independent of force level and that next to EMG, VO(2) can be used for the validation of musculoskeletal models. Expand
Recent developments in near-infrared spectroscopy (NIRS) for the assessment of local skeletal muscle microvascular function and capacity to utilise oxygen
TLDR
Continuous wave near infrared spectroscopy provides non-invasive technology to measure relative changes in oxy- and deoxy-haemoglobin in a dynamic environment and is useable in large population-based samples, including older adults. Expand
Measurement of regional forearm muscle haemodynamics via the near-infrared spectroscopy venous occlusion technique: the impact of hand circulatory occlusion.
TLDR
Findings indicate that hand-occlusion, via wrist cuffing, adversely impacts on regional forearm haemodynamics as determined by the near-infrared spectroscopy (NIRS) venous occlusion technique (NirSVOT), and it is recommended that future investigators avoid hand-OCclusion when using the NIRS-VOT to quantify spontaneous haemodynamic impacts of regional forearm muscle. Expand
Comparison of muscle O(2) dynamics at different sites of the forearm flexor muscles during incremental handgrip exercise.
TLDR
The results in forearm muscle were different from the previous study which found that there were longitudinal differences in muscle VO(2) in the femoral muscle. Expand
Noninvasive evaluation of skeletal muscle mitochondrial capacity with near-infrared spectroscopy: correcting for blood volume changes.
TLDR
In vivo oxidative capacity can be assessed using blood volume-corrected NIRS signals with a high degree of reliability and reproducibility, and this relationship was removed when an ischemic calibration was performed. Expand
A comparison of exercise type and intensity on the noninvasive assessment of skeletal muscle mitochondrial function using near-infrared spectroscopy.
TLDR
NIRS measurements of skeletal muscle mitochondrial function can be compared between VOL and ES exercises and were independent of the intensity of exercise, representing an important new technique that is practical for testing in research and clinical settings. Expand
Forearm oxygen consumption and forearm blood flow in healthy children and adolescents measured by near infrared spectroscopy.
TLDR
It is shown that VO(2) and FBF decreased with increasing age in children and adolescents without significant differences between male and female subjects. Expand
Reliability of near-infrared spectroscopy for measuring forearm and shoulder oxygenation in healthy males and females
TLDR
Establishing reliability data for the ECR and TD and including variables commonly reported are expected to have meaning for future NIRS studies of work-related upper-extremity pain as well as for other N IRS research and clinical applications. Expand
...
1
2
3
4
5
...

References

SHOWING 1-10 OF 47 REFERENCES
Validation of measurement protocols to assess oxygen consumption and blood flow in the human forearm by near-infrared spectroscopy
Near infrared spectroscopy (NIRS) has been used to monitor oxygenation changes in muscle. Quantitative values for O2 consumption, blood flow and venous saturation have been reported by severalExpand
Noninvasive measurement of forearm blood flow and oxygen consumption by near-infrared spectroscopy.
TLDR
The results demonstrate that NIRS provides the particular advantage of obtaining the contemporary evaluation of blood flow and VO2, allowing correlation of these two variables by a single maneuver without discomfort for the subject. Expand
Near-infrared estimation of O2 supply and consumption in forearm muscles working at varying intensity.
TLDR
It is demonstrated that analysis of NIR signals during venous occlusion provides an advantageous method of estimation of O2 supply and consumption in working muscles during exercise of varying intensity. Expand
Comparison of two methods of measuring forearm oxygen consumption (VO2) by near infrared spectroscopy.
TLDR
The results showed that NIRS is a useful tool for the measurement of VO2 and the venous occlusion method was the method of choice because it could be easily repeated at the bedside without causing any discomfort to the patient. Expand
Determination of oxygen consumption in muscle during exercise using near infrared spectroscopy
TLDR
NIRS appeared to be a reproducible and reliable method for the non‐invasive measurement of VO2 in human muscles and could be used to investigate regional differences as well as changes in time between muscle groups as a function of training. Expand
Near infrared spectroscopy for noninvasive assessment of claudication.
TLDR
NIRS appears to be an effective noninvasive method for assessing the imbalance between oxygen demand and oxygen delivery in the leg muscles of PAOD patients at rest and during exercise. Expand
The oxygen consumption of human skeletal muscle in vivo
  • R. Mottram
  • Chemistry, Medicine
  • The Journal of physiology
  • 1955
TLDR
Attempts to measure metabolic activity of skeletal muscle in vivo began with the experiments of Chauveau & Kaufmann (1887) and have followed the same principle in studies on the human forearm muscles. Expand
Measurement of hemoglobin flow and blood flow by near-infrared spectroscopy.
TLDR
A noninvasive method of measuring hemoglobin flow through an organ by near-infrared spectroscopy (NIRS) is described that allows blood flow to be calculated and uses a small change in arterial oxyhemoglobin concentration as an intravascular tracer as a measure of tracer accumulation. Expand
Validation of near-infrared spectroscopy in humans.
TLDR
760-800 nm absorption is closely correlated with venous oxygen saturation, minimally affected by skin blood flow, altered by changes in limb perfusion, and primarily derived from deoxygenated hemoglobin and not myoglobin. Expand
Noninvasive detection of skeletal muscle underperfusion with near-infrared spectroscopy in patients with heart failure.
TLDR
The data suggest that near-infrared spectroscopy can detect impaired skeletal muscle O2 delivery in patients with heart failure, and this technique could provide a valuable method of assessing Muscle O2 Delivery in patients, particularly before and after therapeutic interventions. Expand
...
1
2
3
4
5
...