• Corpus ID: 85508373

Past , Present , and Future Research Toward Air Curtain Performance Optimization

@inproceedings{NavazPastP,
  title={Past , Present , and Future Research Toward Air Curtain Performance Optimization},
  author={Homayun K. Navaz and Mazyar Amin and Dana Dabiri and Ramin Faramarzi}
}

Figures from this paper

A novel circulated air curtain system to confine the transmission of exhaled contaminants: A numerical and experimental investigation
TLDR
A circulated air curtain composed of end-to-end plane jets generated by a relay of air pillars is proposed to confine exhaled contaminants in this study and results can provide a reference for the subsequent design and improvement in applying air curtain in hospital wards or other places.
Optimized cold chain to save food
Abstract The cold chain is an essential component of the food production and distribution system. This chapter reviews the main stages and technologies used for the preservation of perishable food
Comprehensive study on the effects of fluid dynamics of air curtain and geometry, on infiltration rate of open refrigerated cavities
Abstract To date, almost all the studies regarding the improvement of efficiency in open refrigerated display cases by improving the performance of air curtains have been limited to individual cases,
Simulation of multi-deck medium temperature display cabinets with the integration of CFD and cooling coil models
In this paper, the model for the multi-deck medium temperature display cabinets is developed with the integration of CFD and cooling coil sub-models. The distributed method is used to develop the
Air Curtains Integrity When Misusing the Refrigerated Display Cabinets
Tilted air curtains are used as barriers between two environments of different temperature, humidity and quality and are the core elements in Refrigerated display cabinets. Energy consumption and
Visualizing The Flow Induced By An Air Curtain Over A Mannequin Using Stereo Particle Image Velocimetry
The flow of an air curtain mounted above a doorway in which was placed a manne- quin was studied using stereo particle image velocimetry. The study revealed that the interfer- ence of the air curtain
THREE-DIMENSIONAL CFD MODELLING AND ANALYSIS OF THE THERMAL ENTRAINMENT IN OPEN REFRIGERATED DISPLAY CABINETS
This study presents a three-dimensional Computational Fluid Dynamics (CFD) simulation of the air flow pattern and the temperature distribution in a refrigerated display cabinet. The thermal

References

SHOWING 1-10 OF 10 REFERENCES
Jet entrainment minimization in an air curtain of open refrigerated display case
Purpose – To address the effects of velocity profile at the discharge air grille (DAG) on the amount of entrained air into an open refrigerated display case (ORDC).Design/methodology/approach – The
Air curtain design in a vertical open display cabinet
  • 2002
PIV investigation of air - curtain entrainment in open display cases
  • 2002
The Application of Advanced Methods in Analyzing the Performance of the Air Curtain in a Refrigerated Display Case
Computational Fluid Dynamics (CFD) modeling is effectively coupled with the experimental technique of Digital Particle Image Velocimetry (DPIV), to study the flowfield characteristics and
A two - dimensional CFD model of a refrigerated display case
  • ASHRAE Transactions
  • 1997
Effects of indoor space conditions on refrigerated display case performance
  • 1991
Optimum heat transfer through turbulent recirculated plane air curtains
  • ASHRAE Transactions
  • 1980
Heat and moisture transfer through recirculated plane air curtains
  • ASHRAE Transactions
  • 1976