Parastomal hernia repair with a 3-D mesh device and additional flat mesh repair of the abdominal wall

@article{Khler2014ParastomalHR,
  title={Parastomal hernia repair with a 3-D mesh device and additional flat mesh repair of the abdominal wall},
  author={Gernot K{\"o}hler and Oliver Owen Koch and Stavros A Antoniou and Michael Lechner and Franz X. Mayer and Uwe Klinge and Klaus Emmanuel},
  journal={Hernia},
  year={2014},
  volume={18},
  pages={653-661}
}
Parastomal hernias (PSHs) have been a major clinical problem. The aim of this study was to evaluate a new method of PSH repair in combination with an additional flat mesh reinforcement of the abdominal wall. In a pilot case series, seven patients suffering from complex PSHs (≥5 cm diameter and/or recurrence) underwent surgery and were treated by intraperitoneal onlay technique (IPOM) with a synthetic 3-D funnel-shaped mesh implant. The demographics, perioperative, and follow-up data are… CONTINUE READING
6 Citations
27 References
Similar Papers

References

Publications referenced by this paper.
Showing 1-10 of 27 references

Surgical 660 Hernia (2014) 18:653–661 123 techniques for parastomal hernia repair: a systematic review of the literature

  • BM Hansson, NJ Slater, +4 authors RP Bleichrodt
  • Ann Surg
  • 2012
2 Excerpts