Palmar fixation of dorsally displaced distal radius fractures using locking plates with Smartlock locking screws.

@article{Wong2009PalmarFO,
  title={Palmar fixation of dorsally displaced distal radius fractures using locking plates with Smartlock locking screws.},
  author={T C M Wong and Chin Chin Yeung and Yin Ting Chiu and Sue Yeung and Fu Keung Ip},
  journal={The Journal of hand surgery, European volume},
  year={2009},
  volume={34 2},
  pages={173-8}
}
We performed a prospective cohort study on a consecutive series of 35 unstable, dorsally displaced distal radius fractures, which were treated with palmar locking plates and SmartLock locking screws. There were 17 men and 18 women with a mean age of 44 years who were reviewed at a mean follow-up of 10 months. All the fractures healed at a mean time of 7 weeks. Radiographs did not show any change in alignment from the initial postoperative period until fracture union. The average Mayo wrist… CONTINUE READING