PV generator performance using Cassy System

@article{Belhadj2013PVGP,
  title={PV generator performance using Cassy System},
  author={C. A. Belhadj and Shakeel Ahmed and Mahmoud Kassas},
  journal={2013 International Conference on Renewable Energy Research and Applications (ICRERA)},
  year={2013},
  pages={511-515}
}
This paper presents an experimental investigation for the performance of a PV generator using Cassy System environment. Two PV panels were exposed to severe environmental conditions such as high temperature, high humidity, relatively high irradiation and frequently high levels of dust deposition. Each PV panel of 150 W rating was feeding a variable resistive load. The measurement was taken through a conditioning amplifier and Profi-Cassy analog to a digital converter. Cassy System displayed the… CONTINUE READING
0 Extracted Citations
7 Extracted References
Similar Papers

Referenced Papers

Publications referenced by this paper.
Showing 1-7 of 7 references

Nor “Integrated PV Based Solar Insolation Measurement and Performance Monitoring System

  • N. S. Hussain, N.a. Zainal, B.S.M. Singh, N. M. Mohamed, N.M
  • IEEE Colloquium on Humanities, Secience and…
  • 2011
1 Excerpt

Development of a monitoring system for a PV solar plant

  • N. Forero, J. Herna, G. Gordillo
  • Elsevier, Journal of Energy Conversion and…
  • 2006
1 Excerpt

I-Wern “Development of a LabVIEW-based test facility for standalone PV systems

  • A. S. Kok Bin, S. Weixiang, O. K. Seng, S L.Ramanathan
  • Third IEEE International Workshop on Electronic…
  • 2006
2 Excerpts

Measurements, analyses and evaluation of residential PV systems by Japanese monitoring program

  • T. Sugiuraa, T. Yamadaa, H. Nakamuraa, M. Umeyaa, K. Sakutab, K. Kurokawac
  • Elsevier, Solar Energy Materials & Solar Cells 75…
  • 2003
1 Excerpt

Similar Papers

Loading similar papers…