PRECISE THROUGHPUT DETERMINATION OF THE PanSTARRS TELESCOPE AND THE GIGAPIXEL IMAGER USING A CALIBRATED SILICON PHOTODIODE AND A TUNABLE LASER: INITIAL RESULTS

@article{Stubbs2010PRECISETD,
  title={PRECISE THROUGHPUT DETERMINATION OF THE PanSTARRS TELESCOPE AND THE GIGAPIXEL IMAGER USING A CALIBRATED SILICON PHOTODIODE AND A TUNABLE LASER: INITIAL RESULTS},
  author={Christopher W. Stubbs and Peter E. Doherty and Claire E. Cramer and Gautham Narayan and Yorke J. Brown and Keith R. Lykke and John T. Woodward and John L. Tonry},
  journal={The Astrophysical Journal Supplement Series},
  year={2010},
  volume={191},
  pages={376 - 388}
}
We have used a precision-calibrated photodiode as the fundamental metrology reference in order to determine the relative throughput of the PanSTARRS telescope and the Gigapixel imager, from 400 nm to 1050 nm. Our technique uses a tunable laser as a source of illumination on a transmissive flat-field screen. We determine the full-aperture system throughput as a function of wavelength, including (in a single integral measurement) the mirror reflectivity, the transmission functions of the filters… 

Spectrophotometric calibration of the Swope and duPont telescopes for the Carnegie supernova project 2

We present results from the spectrophotometric calibration of the new E2V CCD camera on the Swope telescope and of RetroCam on the DuPont Telescope. We measured the relative sensitivity of each pixel

Testing of the LSST's photometric calibration strategy at the CTIO 0.9 meter telescope

The calibration hardware system of the Large Synoptic Survey Telescope (LSST) is designed to measure two quantities: a telescope's instrumental response function versus wavelength and atmospheric

A collimated beam projector for precise telescope calibration

The precise determination of the instrumental response function versus wavelength is a central ingredient in contemporary photometric calibration strategies. This typically entails propagating

Calibration dome screen for the Large Synoptic Survey Telescope

The Large Synoptic Survey Telescope (LSST) flat-fields must repeatedly trace not only the spatial response variations, but also the chromatic response through the entire optical system, with an

Spectroradiometric calibration of telescopes using laser illumination of flat field screens

It is standard practice at many telescopes to take a series of flat field images prior to an observation run. Typically the flat field consists of a screen mounted inside the telescope dome that is

Building a better flat-field : an instrumental calibration projector for the Large Synoptic Survey Telescope

The Large Synoptic Survey Telescope (LSST) is a next-generation ground-based survey telescope whose science objectives demand photometric precision at the 1% level. Recent efforts towards 1%

The DICE calibration project: design, characterization, and first results

We describe the design, operation, and first results of a photometric calibration project, called DICE (Direct Illumination Calibration Experiment), aiming at achieving precise instrumental

Spectrophotometric calibration system for DECam

We present a spectrophotometric calibration system that will be implemented as part of the DES DECam project at the Blanco 4 meter at CTIO. Our calibration system uses a 2nm wide tunable source to

Measurement of Telescope Transmission Using a Collimated Beam Projector

With the increasingly large number of Type Ia supernova being detected by current-generation survey telescopes, and even more expected with the upcoming Rubin Observatory Legacy Survey of Space and

PHOTOMETRIC CALIBRATION OF THE FIRST 1.5 YEARS OF THE PAN-STARRS1 SURVEY

We present a precise photometric calibration of the first 1.5 years of science imaging from the Pan-STARRS1 survey (PS1), an ongoing optical survey of the entire sky north of declination −30° in five
...

References

SHOWING 1-10 OF 24 REFERENCES

Toward 1% Photometry: End-to-End Calibration of Astronomical Telescopes and Detectors

We review the systematic uncertainties that have plagued attempts to obtain high precision and high accuracy from ground-based photometric measurements using CCDs. We identify two main challenges in

PRECISION DETERMINATION OF ATMOSPHERIC EXTINCTION AT OPTICAL AND NEAR-INFRARED WAVELENGTHS

The science goals for future ground-based all-sky surveys, such as the Dark Energy Survey, PanSTARRS, and the Large Synoptic Survey Telescope, require calibration of broadband photometry that is

SATELLITE-MOUNTED LIGHT SOURCES AS PHOTOMETRIC CALIBRATION STANDARDS FOR GROUND-BASED TELESCOPES

A significant and growing portion of systematic error on a number of fundamental parameters in astrophysics and cosmology is due to uncertainties from absolute photometric and flux standards. A path

PHOTOMETRIC RESPONSE FUNCTIONS OF THE SLOAN DIGITAL SKY SURVEY IMAGER

The monochromatic illumination system is constructed to carry out in situ measurements of the response function of the mosaicked CCD imager used in the Sloan Digital Sky Survey (SDSS). The system is

Linearity of P-N junction photodiodes under pulsed irradiation

Photometric calibration of the Supernova Legacy Survey fields

Aims: We present the photometric calibration of the Supernova Legacy Survey (SNLS) fields. The SNLS aims at measuring the distances to SNe Ia at (0.3 < z < 1) using MegaCam, the 1 deg2 imager on the

Calibration of Synthetic Photometry Using DA White Dwarfs

We have calibrated four major ground-based photometric systems with respect to the Hubble Space Telescope (HST) absolute flux scale, which is defined by Vega and four fundamental DA white dwarfs.

Radiometer standard for absolute responsivity calibrations from 950 nm to 1650 nm with 0.05% (k = 2) uncertainty

A near-IR radiometer standard with similar performance to silicon trap detectors has been developed to calibrate detectors and radiometers for absolute spectral power, irradiance and radiance

The Future of Photometric, Spectrophotometric and Polarimetric Standardization

The OmegaCAM wide-field imager will start operations at the ESO VLT Survey Telescope at Paranal in 2007. The photometric calibration of OmegaCAM data depends on standard-star measurements that cover