PET/CT with intravenous contrast can be used for PET attenuation correction in cancer patients

@article{Berthelsen2005PETCTWI,
  title={PET/CT with intravenous contrast can be used for PET attenuation correction in cancer patients},
  author={Anne Kiil Berthelsen and S{\"o}ren Holm and Annika Loft and Thomas Levin Klausen and Flemming Gorm Andersen and Liselotte H{\o}jgaard},
  journal={European Journal of Nuclear Medicine and Molecular Imaging},
  year={2005},
  volume={32},
  pages={1167-1175}
}
If the CT scan of a combined PET/CT study is performed as a full diagnostic quality CT scan including intravenous (IV) contrast agent, the quality of the joint PET/CT procedure is improved and a separate diagnostic CT scan can be avoided. CT with IV contrast can be used for PET attenuation correction, but this may result in a bias in the attenuation factors. The clinical significance of this bias has not been established. Our aim was to perform a prospective clinical study where each patient… CONTINUE READING
BETA

Citations

Publications citing this paper.
SHOWING 1-10 OF 67 CITATIONS

FILTER CITATIONS BY YEAR

2005
2017

CITATION STATISTICS

  • 4 Highly Influenced Citations

References

Publications referenced by this paper.
SHOWING 1-10 OF 23 REFERENCES

European guidelines on quality criteria for computed tomography

  • K Jessen, W Panzer, 16262. Shrimpton P. EUR
  • Luxemburg: Office for Official publications of…
  • 2000
Highly Influential
3 Excerpts

Estimation of the noise contributions from blank, transmission and emission scans in PET

  • S Holm, PA Toft, M. Jensen
  • IEEE Trans Nucl Sci ;43:2285–91
  • 2005
1 Excerpt

Evaluation of method to minimize the effect of X-ray contrast in PET–CT attenuation correction

  • Lonn AHR
  • IEEE Nuclear Science Symposium. Conference Record…
  • 2003
1 Excerpt

Similar Papers