Ovulation prediction by monitoring salivary electrical resistance with the Cue Fertility Monitor.

@article{Roumen1988OvulationPB,
  title={Ovulation prediction by monitoring salivary electrical resistance with the Cue Fertility Monitor.},
  author={Frans J. M. E. Roumen and Thom O M Dieben},
  journal={Obstetrics and gynecology},
  year={1988},
  volume={71 1},
  pages={49-52}
}
The purpose of this study was to investigate the potential relationship between the salivary electrical resistance, as measured by the Cue Fertility Monitor, and the time of ovulation. Twenty-seven cycles in 18 volunteers were analyzed. A slight correlation could be demonstrated between the day of salivary electrical resistance peak and the day of luteinizing hormone (LH) peak. However, the changes in salivary electrical resistance values, arranged to the day of LH peak, were not statistically… CONTINUE READING